Nexans Marine

NSGAFÖU 3Cx240mm2 6/10kV

Nexans Marine NSGAFÖU 3Cx240mm2 6/10kV — 240 mm² cross-section. The supplied category identifies the equipment as Power Cable (6/10 kV), and it is normally installed in cable trays, penetrations and equipment terminations between switchboards, machinery, sensors or communication systems. In that listed role, its primary purpose is to carry electrical power, control signals or data between shipboard equipment. Power, medium-voltage, fire-resistant, control, instrumentation and communication cables differ in conductor, insulation, screening and fire-performance requirements, so replacement cable must match the approved specification. Within the supplied list, neighbouring variants are distinguished by their model designations and naming, while the source does not state further model-specific hardware differences. No additional performance, approval or construction detail is inferred from the model code beyond the information supplied in the source record. For exact ratings, dimensions, settings, capacities, materials and variant-specific limits, refer to the manufacturer documentation for the exact figure.

Components & Design

Component data being added…

Technical Data

cross section mm2 240
voltage class 6/10kV
cores 3
material Cu
insulation EPR
fire rating IEC60332-1
halogen free False

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Mechanical damage, crushing or excessive bending damages insulation and causes earth faults, conductor failure or intermittent circuits
Loose or corroded terminations create resistance heating and cause voltage drop, discoloration or intermittent signals
Water ingress through damaged sheaths or glands reduces insulation integrity and causes earth-fault alarms or unreliable operation
Heat, oil or chemical exposure degrades insulation and causes cracking, swelling or loss of dielectric integrity
Poor screening, bonding or separation on signal cables introduces electrical noise and causes unstable instrumentation or communication data

Service & Maintenance

Inspect accessible cable runs, supports, penetrations, glands, terminations and signs of heat, oil or mechanical damage. Check insulation condition and termination integrity using an approved test method appropriate to the circuit. Maintain fire stopping, segregation and shielding arrangements at penetrations and terminations. Refer to the cable and connected-equipment documentation for the exact figure for test voltage, bend radius and termination requirements.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Carry approved glands, lugs, ferrules, heat-shrink or jointing materials and representative replacement cable for critical circuits where vessel practice requires it.
Equipment Model #85350 · ✓ still in production