Library› Electrical› Cable & Wiring› Power Cable (0.6/1 kV)› LS Cable DPYC 1Cx1.5mm2 0.6/1kV

DPYC 1Cx1.5mm2 0.6/1kV

Power Cable (0.6/1 kV) · Cable & Wiring

Class-certified type (DNV register) · technical data sheet not yet verified​‌‌​‍⁠​​⁠⁠‍⁠‌⁠⁠⁠​‍‍‍

LS Cable DPYC 1Cx1.5mm2 0.6/1kV — 1.5 mm² cross-section.

Specifications

Technical data.reference — unverified

Do you have the manufacturer datasheet for this model? Send it with the enquiry form — we check it and name the source.

Cross Section (mm²)1.5
Voltage Class0.6/1kV
Cores1
MaterialCu
InsulationXLPE
Fire RatingIEC60332-1
Halogen-FreeNo
Inspection

Inspector Detail

Common issues

  • Insulation resistance degradation from moisture ingress at glands or terminations
  • Mechanical damage/chafing where the cable runs through bulkhead penetrations or along trays without adequate support
  • Overheating/discoloration at overloaded or poorly torqued terminations
  • Jacket cracking or embrittlement from UV/heat exposure on engine room runs
  • Incorrect fire-stop sealing at multi-cable transits

Inspection checklist

  • Insulation resistance test between conductors and to earth
  • Visual inspection of jacket condition along accessible runs, particularly at bends and penetrations
  • Check gland and termination tightness, look for discoloration/heat damage
  • Verify cable support/cleating is intact and not causing chafe points
  • Check fire-stop transit sealing at bulkhead/deck penetrations
  • Confirm cable identification/labeling is legible

Service intervals

Insulation resistance testtypically annually or per the class electrical survey cycle
Visual inspection of accessible runstypically at each annual survey
Termination re-torque checktypically at annual survey for high-load circuits

Typical intervals for this design class, not the manufacturer’s figures for your model. The manufacturer’s manual is binding.

Typical wear limits

Insulation resistancecommonly expected not less than about 1 M-ohm as a general minimum, though class/flag may set a higher figure for this voltage class - confirm against the applicable rules
Jacket condition at chafe pointsany exposed conductor insulation requires immediate repair or renewal

Ranges are typical for this design class. Always confirm against the manufacturer documentation for your serial number.

Critical spares

  • Matching cross-section/voltage-class cable length
  • Cable glands
  • Ferrules/lugs
  • Fire-stop transit sealing kits

Safety

  • Electric shock risk during testing or termination work - isolate and lock out before work
  • A damaged fire-rated jacket or wrong halogen content changes fire/smoke performance in escape routes - use only maker-equivalent replacement cable
  • Overloaded cables are a fire ignition source

Class survey

Marine power cables are checked at periodic electrical survey for insulation resistance, physical condition, and correct fire-stop sealing at transits; class rules typically require replacement cable to match the original type approval (insulation, fire performance, halogen-free status) rather than an equivalent selected by cross-section alone.

Need this part?

Request a quote for this model.

Free of charge — send us your request for LS Cable equipment. Our team checks it and replies by e-mail.

For marine equipment hardly any maker or authorised dealer will name a price while the vessel is unknown. With the vessel details, availability and price can be settled faster; without them we may have to ask first, which costs a few days. If you are not allowed to name the vessel, a photo of the rating plate is enough — attach it below or send it as a reply to our confirmation e-mail.

Your contact details are not published. No account required.
Related models

Also in Power Cable (0.6/1 kV).

Other models of the same equipment type, LS Cable first.

By manufacturer Draka/PrysmianPrysmianHelkama BicaNexansLS CableEland CablesNKT MarineTMC MarineTKF/TKDUNIKAStuder CablesSEIMIElettrotek KabelTMC CableAmerCableAll manufacturersSpare parts by equipmentNew here? Create a free account Can't read the plate? Try the nameplate scanner All LS Cable models More like DPYC 1Cx1.5mm2 0.6/1kV
More than the data sheet shows

We answer by e-mail, never with an automatic reply.

Tell us what you need for this LS Cable DPYC 1Cx1.5mm2 0.6/1kV — a part, a service call, a second opinion. Are you LS Cable? Claim this brand page.

Service engineer? Write the day report for this DPYC 1Cx1.5mm2 0.6/1kV in OceanSphere Work — photos, hours and parts, as a PDF for the owner. Try it free for 14 days →

Frequently asked

Questions that come up with this equipment.

Is this model's data free?

Yes. Specifications, documents and service notes for this model are readable without an account. An account adds saved searches and requests, nothing is taken away.

Can you find a part for this exact model?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.

The specifications look wrong — what now?

Send us the nameplate or the correct value. We check it against the manufacturer datasheet or class-society record and update the page.