DPYC 1Cx1.5mm2 0.6/1kV
LS Cable DPYC 1Cx1.5mm2 0.6/1kV — 1.5 mm² cross-section.
Inspector Detail
▸
Common issues
- Insulation resistance degradation from moisture ingress at glands or terminations
- Mechanical damage/chafing where the cable runs through bulkhead penetrations or along trays without adequate support
- Overheating/discoloration at overloaded or poorly torqued terminations
- Jacket cracking or embrittlement from UV/heat exposure on engine room runs
- Incorrect fire-stop sealing at multi-cable transits
Inspection checklist
- Insulation resistance test between conductors and to earth
- Visual inspection of jacket condition along accessible runs, particularly at bends and penetrations
- Check gland and termination tightness, look for discoloration/heat damage
- Verify cable support/cleating is intact and not causing chafe points
- Check fire-stop transit sealing at bulkhead/deck penetrations
- Confirm cable identification/labeling is legible
Service intervals
| Insulation resistance test | typically annually or per the class electrical survey cycle |
| Visual inspection of accessible runs | typically at each annual survey |
| Termination re-torque check | typically at annual survey for high-load circuits |
Typical wear limits
| Insulation resistance | commonly expected not less than about 1 M-ohm as a general minimum, though class/flag may set a higher figure for this voltage class - confirm against the applicable rules |
| Jacket condition at chafe points | any exposed conductor insulation requires immediate repair or renewal |
Ranges are typical for this design class. Always confirm against the manufacturer documentation for your serial number.
Critical spares
- Matching cross-section/voltage-class cable length
- Cable glands
- Ferrules/lugs
- Fire-stop transit sealing kits
Safety
- Electric shock risk during testing or termination work - isolate and lock out before work
- A damaged fire-rated jacket or wrong halogen content changes fire/smoke performance in escape routes - use only maker-equivalent replacement cable
- Overloaded cables are a fire ignition source
Class survey
Marine power cables are checked at periodic electrical survey for insulation resistance, physical condition, and correct fire-stop sealing at transits; class rules typically require replacement cable to match the original type approval (insulation, fire performance, halogen-free status) rather than an equivalent selected by cross-section alone.
Components & Design
Component data being added…
Technical Data
🤖 Ask about this model
One free question — answered like a marine engineer. No account needed.
Suppliers & Spare Parts
Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.
📄 Request sourcing links & documentsCases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.
Start free trial →Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.
Maritime Network →