Schneider Marine

Altivar 930 Marine 1.5kW 690V Marine

Schneider Marine Altivar 930 Marine 1.5kW 690V Marine — 1.5 kW. The supplied category identifies the equipment as Variable Frequency Drive (VFD) / Frequency Converter, and it is normally installed inside an electrical cabinet, machinery-control panel or dedicated drive room close to the motor or distribution system it controls. In that listed role, its primary purpose is to regulate AC motor speed and torque by controlling supply frequency and voltage. Compared with a fixed-speed starter, a frequency converter adds power electronics, cooling, software parameters and communication interfaces. Within the supplied list, this variant is distinguished from neighbouring entries by its model designation and the explicitly listed power; further hardware differences are not stated in the source. No additional performance, approval or construction detail is inferred from the model code beyond the information supplied in the source record. For exact ratings, dimensions, settings, capacities, materials and variant-specific limits, refer to the manufacturer documentation for the exact figure.

1.5 kW
Power

Components & Design

Component data being added…

Technical Data

power kw 1.5
current a 1.3
cooling air
ip rating IP55

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Cooling-fan failure, blocked air paths or dirty heat sinks causes rising drive temperature and overtemperature trips
Power-semiconductor or DC-link deterioration causes overcurrent, DC-bus or hardware-fault alarms and loss of motor operation
Loose or overheated power terminals cause discoloration, insulation damage, nuisance trips or phase-related faults
Incorrect parameters, control signals or fieldbus communication causes unstable speed, failure to start or loss of remote control
Motor-cable insulation faults or earth leakage causes ground-fault trips and can stress the drive output stage

Service & Maintenance

Inspect cabinet cleanliness, cooling fans, heat sinks, power terminals, earthing, control wiring and signs of overheating. Review fault history and confirm motor and process parameters against the approved configuration. Check ventilation and environmental conditions around the drive. Refer to the manufacturer documentation for the exact figure for voltage, torque, switching and insulation limits.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Carry cooling fans, control fuses, contactors where used, approved power-supply or control modules, keypad or display units and backed-up parameter files.
Equipment Model #84308 · ✓ still in production