WEG Marine

CFW11M 160kW 440V Marine

WEG Marine CFW11M 160kW 440V Marine is identified in the source list as a marine variable-frequency drive or frequency converter. It is installed in an electrical cabinet, switchboard room or machinery-control space and connected between the vessel's power distribution system and the driven motor or electrical consumer. Its purpose is to control motor speed, torque or electrical frequency and voltage according to the application and control commands of the connected machinery. The source record provides a stated power of 160.0 kW, and the existing record note '160 kW'. The unit combines power electronics, DC-link components, cooling, control electronics and protection functions, with exact architecture depending on the model and supply voltage. The exact model designation and any kW or voltage values contained in the source distinguish rating and supply class from neighboring drives; refer to the manufacturer documentation for the exact current, overload and environmental figures.

160.0 kW
Power

Components & Design

Component data being added…

Technical Data

power kw 160
current a 210.0
cooling air
ip rating IP44

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Cooling-fan or airflow failure caused by dust, fan wear or blocked filters, resulting in rising internal temperature and overtemperature trips
DC-link capacitor or power-electronic deterioration caused by age, heat or electrical stress, resulting in alarms, unstable operation or inability to start
Input or output connection problems caused by loose terminals, corrosion or insulation damage, resulting in overheating, phase faults or nuisance trips
Control-board, sensor or communication failure caused by electronics faults or network problems, resulting in missing commands, feedback errors or drive faults
Motor or cable insulation problems causing overcurrent or earth-fault trips, resulting in repeated shutdown even though the drive itself may remain serviceable

Service & Maintenance

Keep cabinet ventilation paths, filters and cooling fans clean and verify that internal temperatures remain normal. Inspect power terminals, grounding, cable shields and signs of overheating with the equipment safely isolated. Review fault history and trend recurring alarms before replacing modules. Verify motor parameters, control references and communication links after software or hardware work. Preserve configuration backups and follow approved electrostatic-discharge precautions when handling electronics. Refer to manufacturer documentation for exact electrical tests, capacitor or fan replacement criteria and parameter settings.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Keep model-correct cooling fans, control fuses, keypad or display modules, selected control boards, communication modules and other manufacturer-recommended electronic spares. Critical thruster, pump or fan drives may justify complete power modules or a replacement drive depending on redundancy. Preserve configuration files and verify voltage and rating compatibility before installation.
Equipment Model #84289 · ✓ still in production