"> Mecc Alte ECO28 50kVA 690V 50Hz
⚓ Working on this equipment?
Ask the AI troubleshooter, log your hours on board and turn them into invoice-ready service reports — for this exact model.
Start free — 14 days →
No credit card required
🔧 10 verified suppliers & service companies for Mecc Alte in the Maritime Network Find suppliers →
Mecc Alte

ECO28 50kVA 690V 50Hz

Mecc Alte ECO28 50kVA 690V 50Hz is listed as a Marine Generator / Alternator within the Power Generation category. It is typically installed in the engine room or generator room, coupled to a prime mover and connected to the vessel’s main or emergency electrical distribution system. Its engineering role is to convert mechanical shaft power into electrical power for shipboard consumers. The complete model designation should be retained when matching drawings, certificates, service information and spare parts because neighboring variants may differ in configuration even when they share the same equipment family. The exact shipboard arrangement and interfaces remain installation-specific and should be checked against the vessel’s approved drawings and equipment documentation. Where an operating value, tolerance, wear limit or setting is not explicitly stated in the source data, refer to the manufacturer documentation for the exact figure.

Components & Design

Component data being added…

Technical Data

power kva 50
frequency hz 50
poles 4
enclosure IP23
insulation class H

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Winding insulation deterioration or contamination can cause earth faults or overheating, seen as insulation alarms, trips or abnormal temperature
Bearing wear or lubrication problems can increase vibration and noise, noticed through condition monitoring or audible roughness
Automatic voltage regulator or excitation faults can destabilize voltage, seen as poor voltage control or excitation alarms
Cooling-air restriction can raise internal temperature, seen as overheating alarms or reduced allowable load
Loose terminals or connection faults can create local heating and intermittent output problems, found by inspection or thermal checks

Service & Maintenance

Inspect windings, terminals, bearings, cooling passages, excitation equipment and protective devices. Review insulation condition, vibration and temperature trends and verify stable voltage under normal operating conditions. Electrical test limits and bearing criteria must follow manufacturer documentation.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Carry maker-recommended AVR/excitation parts, fuses, sensors, brushes where applicable, bearing-related service items and common terminal or cooling-system consumables.
Equipment Model #82151 · ✓ still in production