Grasso (GEA)

Grasso V 300 50/10

Grasso (GEA) Grasso V 300 50/10 is identified in the source list as a refrigeration compressor. It is normally installed in a refrigeration machinery room or machinery space as part of a provision, cargo, HVAC or process refrigeration circuit. Its purpose is to compress refrigerant vapor so the refrigeration cycle can reject heat at the condenser and provide cooling at the evaporator. The existing database record states 10 bar. The exact compressor architecture, refrigerant compatibility and capacity-control arrangement are model-specific and must be verified from the installed system documentation. The exact model designation identifies the compressor size and configuration; refrigerant, displacement, capacity-control range and operating envelope must be confirmed from manufacturer data.

Components & Design

Component data being added…

Technical Data

compressor type refrigeration_compressor
pressure bar 10
capacity nm3h 50
refrigerant R717

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Loss of lubrication or oil return caused by low oil level, refrigerant migration or system faults, resulting in bearing noise, high temperature or compressor damage
Valve or internal compression-element wear caused by contamination, liquid carry-over or long service, resulting in poor capacity and abnormal discharge conditions
Refrigerant leakage caused by shaft-seal, gasket or connection deterioration, resulting in loss of charge and reduced refrigeration performance
Liquid slugging caused by inadequate superheat or evaporator-control problems, resulting in knocking, vibration or sudden mechanical damage
Motor, coupling or capacity-control faults caused by electrical or mechanical defects, resulting in trips, unstable suction pressure or inability to match load

Service & Maintenance

Monitor suction and discharge conditions, oil level, oil pressure where applicable, temperatures, vibration and compressor loading. Check for refrigerant and oil leakage and verify that crankcase heating or oil-management equipment operates as designed. Inspect couplings, belts, filters and capacity-control mechanisms where fitted. Investigate any evidence of liquid return or repeated protective trips before restarting. Maintain system cleanliness and use only refrigerant and lubricant approved for the installed design. Refer to the manufacturer documentation for exact operating limits, clearances and overhaul procedures.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Keep model-correct seals, gaskets, oil filters or strainers, approved lubricant and manufacturer-recommended valve or capacity-control service parts. For critical cargo or provision refrigeration, additional compressor-specific wear parts may be justified. Confirm refrigerant compatibility and exact part numbers from the manufacturer documentation.
Equipment Model #80630 · ✓ still in production