Onda S76 2000kW Central cooling

Onda Onda S76 2000kW Central cooling is identified in the source list as a brazed plate heat exchanger. It is normally installed or arranged in the engine-room cooling, heating or process circuit. Its purpose is to transfer heat between separate fluid circuits. The source record provides the existing record note 'Heat Exchangers, Central cooling'. The equipment is based on plate, brazed-plate or shell-and-tube heat-transfer surfaces and connections. The exact model designation distinguishes the installed configuration from neighboring variants in the same category; refer to the manufacturer documentation for the exact figure.

Components & Design

Component data being added…

Technical Data

hx type brazed_plate_heat_exchanger
capacity kw 2000
material titanium

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Heat-transfer surface fouling caused by scale, sludge or biological deposits, resulting in reduced thermal performance and increased pressure drop
Seal, gasket, braze or tube leakage caused by wear, corrosion or thermal cycling, resulting in external leakage or cross-contamination
Plate or tube corrosion caused by incompatible fluid chemistry, resulting in pinholes and contamination between circuits
Blocked flow passages caused by debris or deposits, resulting in uneven flow and abnormal differential pressure
Frame, cover or connection problems caused by incorrect assembly or piping stress, resulting in leakage and mechanical distortion

Service & Maintenance

Trend inlet and outlet temperatures and pressure drop to identify fouling. Inspect frame or covers, port connections and visible sealing areas for leakage or distortion. Clean heat-transfer surfaces using methods compatible with installed materials and deposits. Investigate any evidence of cross-contamination with an approved leak or pressure test. Support connected piping independently so nozzle loads are not transferred into the exchanger. Refer to the manufacturer documentation for the exact figure for tightening, cleaning, pressure-test and repair criteria.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Keep model-correct gaskets or cover seals, selected spare plates or approved tube-repair materials as applicable, port seals and manufacturer-recommended corrosion-protection parts. Brazed units are normally replaced as an assembly after an internal structural leak.
Equipment Model #79342 · ✓ still in production