"> Sondex Sondex S-14 1000kW FW cooling
⚓ Working on this equipment?
Ask the AI troubleshooter, log your hours on board and turn them into invoice-ready service reports — for this exact model.
Start free — 14 days →
No credit card required
Sondex

Sondex S-14 1000kW FW cooling

Sondex Sondex S-14 1000kW FW cooling is identified in the source list as a gasketed plate heat exchanger. It is installed in an engine-room cooling, heating or process circuit between two separate fluid systems. Its purpose is to transfer heat efficiently between fluids while keeping the circuits separated. The source record provides the existing record note 'Heat Exchangers, FW cooling'. A corrugated plate pack provides the heat-transfer surface, with a permanently brazed core used in brazed units and an openable gasketed frame used in gasketed units. The exact model designation and any source-listed surface or duty information distinguish plate size, material and thermal selection from neighboring exchangers; refer to the manufacturer documentation for the exact figure.

Components & Design

Component data being added…

Technical Data

hx type plate_heat_exchanger
capacity kw 1000
material stainless_steel_316

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Plate-channel fouling caused by scale, sludge or biological deposits, resulting in reduced thermal performance and increased pressure drop
Gasket, braze or connection leakage caused by wear, corrosion or thermal cycling, resulting in external leakage or cross-contamination
Plate corrosion caused by incompatible fluid chemistry, resulting in pinholes and contamination between circuits
Blocked channels caused by debris or deposits, resulting in uneven flow and abnormal differential pressure
Frame or connection problems caused by incorrect assembly or piping stress, resulting in leakage and mechanical distortion

Service & Maintenance

Trend inlet and outlet temperatures and pressure drop to identify fouling. Inspect frame or external connections and visible sealing areas for leakage or distortion. Clean heat-transfer surfaces using methods compatible with plate and sealing materials. Investigate any evidence of cross-contamination with an approved leak or pressure test. Support connected piping independently so nozzle loads are not transferred into the exchanger. Refer to the manufacturer documentation for the exact figure for tightening, cleaning, pressure-test and repair criteria.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Keep model-correct gaskets or connection seals, selected spare plates for openable units, filters and manufacturer-recommended service parts. Brazed units are normally replaced as an assembly after an internal structural leak. Verify materials and dimensions against the exact serial number.
Equipment Model #79136 · ✓ still in production