"> GEA GEA NT 100 200kW LO cooling
⚓ Working on this equipment?
Ask the AI troubleshooter, log your hours on board and turn them into invoice-ready service reports — for this exact model.
Start free — 14 days →
No credit card required
GEA

GEA NT 100 200kW LO cooling

GEA GEA NT 100 200kW LO cooling — Heat Exchangers, LO cooling. The supplied category identifies the equipment as Plate Heat Exchanger, and it is normally installed in an engine-room cooling, heating, condensing or heat-recovery circuit according to the vessel piping arrangement. In that listed role, its primary purpose is to transfer heat between two fluid streams while keeping the media separated. Plate, brazed-plate and shell-and-tube exchangers differ in construction, opening method and repair approach, so cleaning and pressure-boundary service must match the actual design. Within the supplied list, neighbouring variants are distinguished by their model designations and naming, while the source does not state further model-specific hardware differences. No additional performance, approval or construction detail is inferred from the model code beyond the information supplied in the source record. For exact ratings, dimensions, settings, capacities, materials and variant-specific limits, refer to the manufacturer documentation for the exact figure.

Components & Design

Component data being added…

Technical Data

hx type plate_heat_exchanger
capacity kw 200
material stainless_steel_316

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Fouling or scaling increases differential pressure and reduces heat-transfer performance
Gasket, braze, seal or tube-joint deterioration causes external leakage
Plate or tube corrosion, erosion or cracking causes internal cross-contamination between fluid circuits
Blocked strainers or restricted valves reduce flow and produce abnormal inlet-to-outlet temperatures
Incorrect reassembly, venting or flow distribution after service causes leakage or poor thermal performance

Service & Maintenance

Trend inlet and outlet temperatures and differential pressure and inspect for leakage. Open or clean the exchanger only by the approved method and examine plates, tubes, gaskets or end covers for deposits, corrosion and deformation. Investigate cross-contamination promptly. Refer to the manufacturer documentation for the exact figure for tightening, test pressure and wear limits.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Carry the correct gaskets or seals, representative plates or tube-repair provisions where approved, port seals, strainers and compatible cleaning materials.
Equipment Model #78900 · ✓ still in production