Saacke FMB 25t/7bar
Saacke Saacke FMB 25t/7bar — HFO/MDO.
Inspector Detail
▸
Common issues
- Burner nozzle fouling or coking from poor HFO atomisation or wrong viscosity at the burner
- Furnace refractory cracking from thermal cycling
- Soot deposits on fire-side tube surfaces reducing heat transfer efficiency
- Feedwater/boiler water treatment excursions causing scale or corrosion
- Safety valve seat leakage from wear or deposits
- Economiser tube fouling or cold-end corrosion on sulphur-bearing fuel
- Combustion air (FD) fan bearing wear
- Flame scanner fouling causing nuisance trips
Inspection checklist
- Fire-side tube soot deposit inspection
- Water-side scale inspection at manhole/handhole openings
- Safety valve lift and reseat test
- Burner nozzle spray pattern and atomising pressure check
- Boiler water chemistry test (alkalinity, chlorides, TDS, phosphate/oxygen scavenger residual)
- Refractory condition check
- Combustion analysis (O2, CO, smoke) at the burner
- Low-water alarm and cut-out function test
- Economiser tube condition where fitted
Service intervals
| Boiler water chemistry test | daily to weekly per the class-approved treatment programme |
| Blowdown (bottom and surface) | daily or per watchkeeping routine |
| Safety valve function test | at each survey or per class requirement, typically annually |
| Burner nozzle cleaning/replacement | per running hours and fuel quality, commonly 500-1500 h |
| Internal inspection (fire-side and water-side) | annually or at the class survey interval |
| Low-water alarm/cut-out test | monthly and before each start after lay-up |
Typical wear limits
| Furnace/fire-side tube wall thickness | condemning limit is boiler-specific per class rules and original design thickness - confirm against the boiler's class-approved thickness gauging record |
| Safety valve set-pressure drift | acceptable tolerance is typically within a few percent of set pressure per class rules - confirm against the valve's certificate |
Ranges are typical for this design class. Always confirm against the manufacturer documentation for your serial number.
Critical spares
- Burner atomiser/nozzle set
- Safety valve spare parts (seat/spring kit, or a complete spare valve)
- Flame scanner
- Feedwater pump seal kit
- Gaskets for manhole/handhole covers
- Boiler water treatment chemicals (correct type for this boiler)
Safety
- Pressurised steam and hot surfaces - scalding risk at manhole/handhole and blowdown lines
- Furnace explosion risk from unburnt fuel accumulation - always purge before relight
- HFO handling at the burner - hot, pressurised fuel lines
- Safety valve discharge path must be kept clear
- Confined space entry for internal inspection - isolate, cool, and gas-free before entry
Class survey
Boilers are subject to periodical survey (internal and external) under the applicable class rules, including safety valve testing, thickness gauging where required, and confirmation that the water treatment log and blowdown records are being maintained.
Components & Design
Component data being added…
Technical Data
🤖 Ask about this model
One free question — answered like a marine engineer. No account needed.
Suppliers & Spare Parts
Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.
📄 Request sourcing links & documentsCases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.
Start free trial →Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.
Maritime Network →