GE Marine GE OMD-5 20ch is identified in the source list as a oil-mist detector. It is installed on or near a large diesel engine with sampling connections from crankcase compartments to a detector or scanner unit. Its purpose is to detect an abnormal increase in crankcase oil mist that may precede a hot-bearing event or crankcase explosion hazard. The source record provides no additional model-specific operating figure beyond the listed designation and category. The exact sampling method, number of channels, optical sensing arrangement, alarm logic and engine interface depend on the installed detector model. The exact model designation and any channel count contained in the source name distinguish monitoring capacity and hardware generation from neighboring detectors; refer to manufacturer documentation for the exact configuration.

Components & Design

Component data being added…

Technical Data

detection method scattered light
alarm threshold mg l 2.5
channels 20
engine cylinders max 20

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Sampling-line blockage caused by oil deposits or contamination, resulting in weak flow, channel faults or delayed detection
Optical-cell contamination caused by oil film or dirt, resulting in false alarms, poor sensitivity or cleaning warnings
Fan, pump or suction failure caused by mechanical or electrical faults, resulting in loss of sample flow
Sensor or electronics fault caused by aging, moisture or power problems, resulting in channel alarms or unstable readings
Incorrect zeroing or calibration caused by poor maintenance procedure, resulting in nuisance alarms or reduced detection sensitivity

Service & Maintenance

Inspect and clean sampling lines, detector chambers, filters and optical components according to the approved procedure. Verify sample-flow indications for all engine compartments and investigate recurring channel faults. Function-test alarms and any engine interface without bypassing protective functions beyond the authorized test method. Check power supplies, drains and heater or fan arrangements where fitted. Record cleaning, calibration and sensor replacement work because trend changes can indicate developing contamination. Refer to manufacturer and engine documentation for exact alarm settings, calibration methods and test intervals.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Keep filters, seals, sampling-line fittings, optical components where applicable, fan or pump service parts and manufacturer-recommended electronic modules. Use only components compatible with the approved engine protection system. Maintain cleaning tools and consumables specified by the manufacturer.
Equipment Model #70854 · ✓ still in production