Kongsberg Maritime K-Chief 700 8000pt is a shipboard unit in the Automation & Control group, classified in the source as Integrated Automation System (IAS). It is normally installed in engine control rooms, bridge consoles, machinery automation cabinets and distributed I/O panels throughout the vessel. Its primary duty is to monitor machinery and process conditions, generate alarms, execute control logic and coordinate safety or power-management functions. In service it interfaces with sensors, actuators, PLCs, remote I/O, communication networks, operator stations, switchboards and safety systems. Compared with neighboring entries in the same product family, this record is the exact Kongsberg Maritime K-Chief 700 8000pt variant; the model designation should be retained unchanged when matching onboard documentation and spares. For exact limits, settings, test values and approved maintenance criteria, refer to the manufacturer documentation for the exact figure.

Components & Design

Component data being added…

Technical Data

io points 8000
protocol Ethernet/Modbus
class approved DNV/LR/ABS

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Power-supply or UPS fault in control cabinets, typically indicated by loss of modules, blank operator stations or widespread communication alarms
Network or communication failure from damaged cabling, switches or configuration issues, typically indicated by multiple device timeouts, stale values or loss of remote control
I/O module or channel failure from electronics damage or field short circuits, typically indicated by single-point bad values, frozen signals or failed commands
Sensor drift or actuator feedback failure, typically indicated by implausible process readings, control hunting or alarm mismatch
Software/configuration corruption or controller fault, typically indicated by unexpected logic behavior, rebooting or loss of redundancy

Service & Maintenance

Review alarm/event logs, controller redundancy, network health, cabinet cooling, power supplies, I/O condition, sensor calibration status and backup copies of software/configuration; test critical safety and control functions under approved procedures.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Carry critical power supplies, I/O modules, network switches, operator-interface components, communication converters, relays and backed-up software/configuration media as permitted by the vessel's control policy.
Equipment Model #70453 · ✓ still in production