"> Yara Marine EGR-750 closed-loop
⚓ Working on this equipment?
Ask the AI troubleshooter, log your hours on board and turn them into invoice-ready service reports — for this exact model.
Start free — 14 days →
No credit card required
🔧 152 verified suppliers & service companies for Yara Marine in the Maritime Network Find suppliers →
Yara Marine

EGR-750 closed-loop

Yara Marine EGR-750 closed-loop — Exhaust Gas Cleaning. The supplied category identifies the equipment as Exhaust Gas Cleaning System (Scrubber), and it is normally installed in the exhaust-gas or tanker cargo-support plant with fans or blowers, treatment vessels, pumps, monitoring and control equipment. In that listed role, its primary purpose is to clean exhaust gas or provide a controlled low-oxygen or inert atmosphere according to the listed system. Scrubbers, flue-gas inert systems, nitrogen generators and inert-gas generators use different processes, so treatment chemistry, gas quality and safety interlocks remain system-specific. The model designation identifies the listed configuration, but no additional performance, approval or construction detail is inferred from the model code beyond the information supplied in the source record. For exact ratings, dimensions, settings, capacities, materials and variant-specific limits, refer to the manufacturer documentation for the exact figure.

Components & Design

Component data being added…

Technical Data

engine power kw 750
scrubber type closed-loop
sox reduction pct 98
imo compliant True

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Fouling, scaling or blocked spray paths reduce treatment effectiveness and cause abnormal pressure drop or emissions readings
Pump, blower or fan faults cause low circulation or gas flow and system shutdown
Analyzer or sensor contamination causes incorrect gas-quality, emissions or oxygen readings
Seal, valve or piping leakage causes liquid or gas leakage and unstable process pressure
Control, dosing or interlock faults cause off-specification gas, alarm conditions or automatic shutdown

Service & Maintenance

Inspect treatment vessels or generators, pumps, fans or blowers, spray or filtration equipment, analyzers, drains and control interlocks. Trend gas quality, pressure drop and liquid-treatment condition where applicable. Verify shutdown and isolation functions according to the approved procedure. Refer to manufacturer, vessel and statutory documentation for the exact figure for gas quality, emissions, pressure and chemical limits.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Carry pump and valve seals, analyzer consumables, filters, spray nozzles, dosing parts, fan or blower service items, sensors and control relays.
Equipment Model #70287 · ✓ still in production