"> Novenco Novenco AHU-M 25
⚓ Working on this equipment?
Ask the AI troubleshooter, log your hours on board and turn them into invoice-ready service reports — for this exact model.
Start free — 14 days →
No credit card required
🔧 7 verified suppliers & service companies for Novenco in the Maritime Network Find suppliers →
Novenco

Novenco AHU-M 25

Novenco Novenco AHU-M 25 is a marine air-handling unit in the supplied category 'Air Conditioning / AHU (Air Handling Unit)'. It is normally installed in an accommodation HVAC plant room or machinery ventilation space. It is intended to move, filter, heat or cool ventilation air before distribution through the vessel. Compared with neighbouring entries in the same series, the supplied data identifies this variant by a supplied power rating of 22.0 kW, a supplied capacity of 12500 m³/h. In service it interfaces with ductwork, fans, filters, heating or cooling coils, dampers, drains, controls and the vessel's chilled-water or heating system where fitted. Model-specific limits, settings, dimensions and acceptance criteria that are not stated in the supplied data should be taken from the manufacturer documentation.

22.0 kW
Power
12500 m³/h
Capacity

Components & Design

Component data being added…

Technical Data

unit type marine AHU
airflow 12500 m³/h
fan power kw 22

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Dirty filters restrict airflow, noticed as poor ventilation and increased fan load
Fan bearing or belt faults cause noise, vibration or reduced air delivery
Blocked condensate drains cause water leakage or standing water in the casing
Fouled heating or cooling coils reduce temperature-control performance
Damper actuator or control-sensor faults cause unstable airflow or room temperature

Service & Maintenance

Inspect filters, fans, bearings, belts where fitted, coils, drains, dampers and casing condition. Check airflow, temperature-control response and vibration and clean coils and drain pans as required. Exact filter grades, belt tension and control settings must follow manufacturer and vessel HVAC documentation.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Carry replacement filters, fan belts where applicable, bearings or motor service parts, drain seals and common actuator or sensor components.
Equipment Model #68550 · ✓ still in production