Danfoss VLT FC302 Marine 160kW

Danfoss VLT FC302 Marine 160kW variable frequency drive. The supplied category identifies the equipment as Variable Frequency Drive, and it is normally installed in a motor-control centre, switchboard, local starter panel or dedicated drive cabinet. In that listed role, its primary purpose is to start, protect or regulate an electric motor according to the connected machinery duty. Direct-on-line starters, soft starters, protection switches and VFDs differ in switching and speed-control capability, but all depend on sound power connections, protection settings and control circuits. The model designation identifies the listed configuration, but no additional performance, approval or construction detail is inferred from the model code beyond the information supplied in the source record. The source metadata also states power: 160.0 kW. For exact ratings, dimensions, settings, capacities, materials and variant-specific limits, refer to the manufacturer documentation for the exact figure.

160.0 kW
Power

Components & Design

Component data being added…

Technical Data

series VLT FC302
power kw 160.0

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Contactor, semiconductor or control-module faults cause failed starts, irregular operation or drive alarms
Loose or overheated power terminals cause discoloration, insulation damage and phase-related trips
Cooling-fan or ventilation failure in electronic drives causes rising temperature and overtemperature shutdown
Incorrect protection, parameter or control-signal settings cause nuisance trips, poor acceleration or unstable speed
Motor-cable insulation, earth or communication faults cause protective trips and loss of remote control

Service & Maintenance

Inspect terminals, contactors or power electronics, cooling, earthing, protection devices, control wiring and fault history. Confirm configuration and protection settings against the approved motor and system data. Look for heat damage and contamination inside the enclosure. Refer to the manufacturer documentation for the exact figure for settings, torque values and electrical limits.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Carry fuses, contactors, overload or protection modules, cooling fans, control power supplies, relays and backed-up drive parameters where applicable.
Equipment Model #68213 · ✓ still in production