Leroy-Somer

LSA 53.1

The Leroy‑Sommer LSA 53.1 is a high‑power (≈2 MVA) diesel‑driven generator set designed for shipboard electricity generation, notable for its modular construction and integrated control system. The supplied category identifies it as Generator Set, and it is normally installed in the engine room or generator space as an integrated prime mover, alternator, control and protection assembly. In that role, its primary purpose is to produce electrical power for ship service, auxiliary loads or standby duties. A generator set combines the prime mover and alternator, so mechanical engine condition, electrical generation and control-system performance must be assessed together. Within the supplied list, neighbouring variants are distinguished by their model designations and naming, while the source does not state further model-specific hardware differences. No additional performance, approval or construction detail is inferred from the model code beyond the information supplied in the source record. For exact ratings, dimensions, settings, capacities, materials and variant-specific limits, refer to the manufacturer documentation for the exact figure.

Components & Design

Component data being added…

Technical Data

series LSA
power kva 2000

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Fuel, injection or combustion faults cause unstable speed, smoke, poor load acceptance or high exhaust temperatures
Cooling or lubrication faults cause high temperature, low pressure alarms or protective shutdown
Alternator excitation, AVR or winding faults cause unstable voltage or loss of electrical output
Governor, speed-sensor or control faults cause frequency instability, hunting or failed synchronization
Breaker, protection or communication faults prevent connection to the bus or cause nuisance trips

Service & Maintenance

Inspect engine fuel, lubrication and cooling systems, alternator, mounts, coupling, exhaust, governor, AVR and protection. Trend load balance, exhaust temperature, oil pressure, coolant temperature, frequency and voltage where available. Test synchronization and load acceptance under an approved electrical procedure. Refer to the manufacturer documentation for the exact figure for engine, generator and protection limits.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Carry engine filters, belts where fitted, seals, sensors, starter or control relays, AVR or excitation spares where justified, fuses and approved lubricants.
Equipment Model #68155 · ✓ still in production