"> Hansvik Poland Sp. z o.o. 14.5 STANDARD
⚓ Working on this equipment?
Ask the AI troubleshooter, log your hours on board and turn them into invoice-ready service reports — for this exact model.
Start free — 14 days →
No credit card required
Hansvik Poland Sp. z o.o.

14.5 STANDARD

14.5 STANDARD by Hansvik Poland Sp. z o.o.. DNV RCD certificate RCDA100001FB.

Inspector Detail

Common issues

  • Gelcoat crazing and UV degradation on exposed topside surfaces
  • Osmotic blistering below the waterline on GRP hulls where lamination or barrier coating is inadequate
  • Corrosion or seizure of through-hull fittings and seacocks
  • Deck fitting and stanchion base leaks allowing water into a cored deck laminate
  • Electrolytic corrosion of underwater metal fittings where bonding or anodes are neglected

Inspection checklist

  • Visual survey of the hull below the waterline for blistering, cracking or impact damage
  • Check all through-hull fittings and seacocks for free operation and corrosion
  • Inspect the deck for soft spots indicating core delamination
  • Verify sacrificial anodes are present and not fully wasted
  • Check steering, control linkages and fittings appropriate to the craft's layout for wear
  • Confirm the RCD/CE identification plate and hull identification number are legible and match documentation

Service intervals

Sacrificial anode inspection every 12 months, or sooner if wastage is visibly advanced
Out-of-water hull survey (blistering, through-hull fittings) every 2-3 years, or per class/insurer requirement
Seacock/through-hull fitting exercise and grease every 12 months

Critical spares

  • Sacrificial anodes of the correct size for the fitted through-hull metals
  • Seacock/through-hull service kit (grease, valve seat where serviceable)
  • Gelcoat or epoxy repair kit matching hull colour for minor damage
  • Bilge pump and float switch appropriate to the craft's installed system

Safety

  • Seacock or through-hull fitting failure below the waterline
  • Loss of buoyancy or stability if hull damage or core saturation is not identified
  • Fuel or gas system leaks in enclosed compartments on powered craft

Class survey

RCD (Recreational Craft Directive) approval confirms design category and construction compliance at build; it is not a periodic condition survey. The underlying hull material, propulsion and specific equipment fit are not established from the certificate reference alone - confirm against the builder's own specification and the vessel's documentation before basing maintenance decisions on this entry. Available data on this model is limited; entry deliberately kept brief rather than assuming details not confirmed.

Components & Design

Component data being added…

Technical Data

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

DNV type approval

Verified against the DNV Approval Finder — the certificate below is issued by DNV, not by us.

Certificate
RCDA100001FB
Certificate holder
Hansvik Poland Sp. z o.o. (Poland)
Valid until
2042-10-23
Open the certificate at DNV →
Equipment Model #60945 · ✓ still in production