Certificate MERD0001N3A by Feuerschutz Jockel GmbH & Co. KG. DNV MER certificate MERD0001N3A.

Inspector Detail

Common issues

  • Hose fabric perishing or cracking from UV and heat exposure in the hose box
  • Coupling thread damage or corrosion on brass/gunmetal fittings
  • Internal lining delamination, reducing flow and increasing pressure loss
  • Hose box or reel stiff or corroded, delaying deployment in an emergency
  • Nozzle mismatched to the coupling standard actually fitted aboard

Inspection checklist

  • Visually check the hose for cuts, abrasion, perishing or mildew
  • Check couplings for damage or corrosion and correct thread engagement with hydrant and nozzle
  • Confirm the hose is correctly flaked or rolled in its box, ready for immediate use
  • Pressure test the hose at the required interval
  • Check the nozzle jet/spray pattern and shut-off function
  • Verify hose length and coupling type match the fire main standard fitted on the vessel

Service intervals

Visual inspection monthly, as part of the routine fire round
Hydrostatic pressure test annually, per SOLAS/flag requirement
Coupling gasket/washer inspection and renewal at each pressure test
Full hose replacement on failing a pressure test, or per the manufacturer's stated service life

Critical spares

  • Replacement hose of the correct length and coupling standard
  • Coupling gaskets/washers
  • Nozzle matching the coupling type fitted
  • Hose reel/box mounting hardware
  • Spanner/key matched to the coupling type

Safety

  • A hose that fails under pressure during an actual fire is a life-safety failure - the annual pressure test is not optional
  • Coupling compatibility across the vessel is safety-critical during an emergency, particularly where shore or sister-ship connections may be needed
  • Hose boxes/reels must remain unobstructed and immediately accessible at all times

Class survey

This record reflects a DNV type-approval certificate rather than a distinct product data sheet, so the content above is general SOLAS fire-hose practice, not certificate-specific detail. Fire hoses are checked at Fire Safety Systems surveys; class expects evidence of the annual pressure test and confirmation that hose count, length and coupling type match the approved fire control plan.

Estimated lifetime: Not a running-hour item; fire hoses are normally taken out of service on failing the annual pressure test, on visible damage, or per the manufacturer's stated shelf/service life (commonly around 10 years for rubber-lined canvas hose) - confirm against the hose's own certificate

Components & Design

Component data being added…

Technical Data

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

DNV type approval

Verified against the DNV Approval Finder — the certificate below is issued by DNV, not by us.

Certificate
MERD0001N3A
Certificate holder
Feuerschutz Jockel GmbH & Co. KG (Germany)
Valid until
2030-08-25
Open the certificate at DNV →
Equipment Model #59957 · ✓ still in production