Power Cable (0.6/1 kV) · Cable & Wiring
The NKOXSekw 0,6/1 kV and NKOXSekw EMC 0,6/1 kV from Tele-Fonika Kable S.A. are shipboard power cables rated 0.6/1 kV, covered by DNV certificate TAE00004HH. The EMC version is intended for installations where electromagnetic screening is needed. The cables are routed on cable trays and through penetrations between generators, switchboards and consumers on board.
Do you have the manufacturer datasheet for this model? Send it with the enquiry form — we check it and name the source.
| Visual route inspection | annually, or per the periodic electrical survey |
|---|---|
| Insulation resistance test | annually |
| Termination/gland inspection | annually |
| Route protection/clearance check | at each periodic fire safety inspection |
Typical intervals for this design class, not the manufacturer’s figures for your model. The manufacturer’s manual is binding.
| Insulation resistance | typically expected above 1 M ohm, or the applicable IEC/class minimum for MV power cables in service - confirm against the vessel's electrical survey acceptance criteria |
|---|---|
| Outer sheath damage | any breach exposing the armour or insulation should be assessed against the maker's repair guidance before the cable is returned to service |
| Termination temperature/condition | any discolouration or heat damage at a termination indicates a poor connection and should be reworked - confirm against the maker's termination instructions |
Ranges are typical for this design class. Always confirm against the manufacturer documentation for your serial number.
Note: this catalog entry's 'typ' field ('Emergency Generator Set') does not match the actual product - this is a fire-resistant medium-voltage power cable used to connect an emergency generator to the distribution system, not the generator set itself; the content above addresses the cable. Class surveyors verify the emergency source cable route/rating supports SOLAS emergency power availability requirements and check insulation resistance records at periodic survey.
Estimated lifetime: Marine fire-resistant MV power cables of this type are typically designed for the vessel's operating life, commonly in the order of 20-25+ years, provided mechanical damage, moisture ingress, and thermal exposure limits are avoided - confirm against the maker's documentation.
Listed in the DNV Approval Finder at the time we recorded it. The certificate is issued by DNV, not by us; check its current status at DNV.
Free of charge — send us your request for Tele-Fonika Kable equipment. Our team checks it and replies by e-mail.
Other models of the same equipment type, Tele-Fonika Kable first.
Tell us what you need for this Tele-Fonika Kable NKOXSekw 0,6/1 kV, NKOXSekw EMC 0,6/1 kV — a part, a service call, a second opinion. Are you Tele-Fonika Kable? Claim this brand page.
Service engineer? Write the day report for this NKOXSekw 0,6/1 kV, NKOXSekw EMC 0,6/1 kV in OceanSphere Work — photos, hours and parts, as a PDF for the owner. Try it free for 14 days →
Yes. Specifications, documents and service notes for this model are readable without an account. An account adds saved searches and requests, nothing is taken away.
Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.
Send us the nameplate or the correct value. We check it against the manufacturer datasheet or class-society record and update the page.