NKOXSekw 0,6/1 kV, NKOXSekw EMC 0,6/1 kV
Medium‑voltage (0.6/1 kV) emergency power cable assembly designed for connection of shipboard emergency generators to the distribution system.
Inspector Detail
▸
Common issues
- Insulation degradation from prolonged heat exposure near hot machinery surfaces
- Mechanical damage during installation from excessive bend radius or crushing
- Moisture ingress at glands or terminations reducing insulation resistance
- Chafing where the cable is not properly clipped or supported along its route
- Poor termination workmanship causing partial discharge at medium-voltage joints
- Other cables laid across the route reducing its fire-survival protection
Inspection checklist
- Visual condition of the outer sheath along the full route
- Cable support/clipping and bend radius compliance
- Gland and termination condition at both the generator and switchboard ends
- Insulation resistance (megger) test
- Continuity and earth continuity check
- Fire-resistant/circuit-integrity route protection intact, with no other cables encroaching on its clearance
- Cable identification/labeling at both ends
Service intervals
| Visual route inspection | annually, or per the periodic electrical survey |
| Insulation resistance test | annually |
| Termination/gland inspection | annually |
| Route protection/clearance check | at each periodic fire safety inspection |
Typical wear limits
| Insulation resistance | typically expected above 1 M ohm, or the applicable IEC/class minimum for MV power cables in service - confirm against the vessel's electrical survey acceptance criteria |
| Outer sheath damage | any breach exposing the armour or insulation should be assessed against the maker's repair guidance before the cable is returned to service |
| Termination temperature/condition | any discolouration or heat damage at a termination indicates a poor connection and should be reworked - confirm against the maker's termination instructions |
Ranges are typical for this design class. Always confirm against the manufacturer documentation for your serial number.
Critical spares
- Matching fire-resistant/circuit-integrity MV cable of the same cross-section and voltage class
- Matching MV cable glands
- MV termination/jointing kit
- Cable lugs of the correct rating
- Cable support clips/cleats matching the installation
Safety
- Medium-voltage shock hazard - proof of dead, isolation, and earthing required before any work (permit to work)
- This cable forms part of the emergency power fire-survival circuit - damage or unauthorised route changes can compromise emergency generator availability during a fire
- MV terminations should only be made or tested by qualified personnel
- A fire-resistant cable installed on an unprotected or incorrect route may still fail in a fire if not installed as approved
Class survey
Note: this catalog entry's 'typ' field ('Emergency Generator Set') does not match the actual product - this is a fire-resistant medium-voltage power cable used to connect an emergency generator to the distribution system, not the generator set itself; the content above addresses the cable. Class surveyors verify the emergency source cable route/rating supports SOLAS emergency power availability requirements and check insulation resistance records at periodic survey.
Components & Design
Component data being added…
Technical Data
🤖 Ask about this model
One free question — answered like a marine engineer. No account needed.
Suppliers & Spare Parts
Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.
📄 Request sourcing links & documentsCases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.
Start free trial →Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.
Maritime Network →DNV type approval
Verified against the DNV Approval Finder — the certificate below is issued by DNV, not by us.
- Certificate
- TAE00004HH