OceanSphereENGINES
Library› Electrical› Power Generation› Shaft Generator / PTO› Wärtsilä Deutschland GmbH Generator Protection Module, GPM 500, Diesel Protection Module, DPM 500

Generator Protection Module, GPM 500, Diesel Protection Module, DPM 500

Shaft Generator / PTO · Power Generation​​⁠‌​‍⁠⁠​​​​‍‌‌​‍⁠​‌

DNV type approval · certificate TAA00000F1 · check status at the register

The Wärtsilä GPM 500 Generator Protection Module (and its counterpart DPM 500 Diesel Protection Module) monitors and safeguards shaft‑driven generators, providing automatic shutdown on overload, reverse power, under/over‑frequency and other fault conditions.

Inspection

Inspector Detail

Common issues

  • Note: this entry is listed under 'Shaft Generator / PTO' but the actual product is the GPM 500 / DPM 500 generator and diesel protection relay module, not a shaft generator itself - the category assignment appears to mislabel the product, and the content below addresses the actual protection/monitoring device.
  • Nuisance tripping from incorrectly applied protection settings
  • CT/VT wiring faults causing false readings or missed trips
  • Communication/bus fault between the module and the generator or engine control system
  • Backup battery depletion causing loss of settings after a power interruption
  • Firmware/parameter mismatch after a software update
  • Relay contact wear from frequent switching cycles

Inspection checklist

  • Verify current protection settings against the ship's approved setting sheet
  • Test trip functions (overload, reverse power, under/over frequency, under/over voltage) via secondary injection or the module's built-in test
  • Check CT/VT wiring and burden
  • Check the communication link to the generator/engine control system
  • Check backup battery condition
  • Review the event/alarm log for repeated or unexplained trips
  • Verify synchronising and load-sharing signals where applicable

Service intervals

Protection function testtypically annual, per class requirement for essential protective devices
Setting verification against setting sheetannual, or after any modification to the generator or its protection
Backup battery replacementper maker's guidance, commonly every 3-5 years
Firmware/software checkat each planned maintenance visit

Typical intervals for this design class, not the manufacturer’s figures for your model. The manufacturer’s manual is binding.

Typical wear limits

Trip time accuracyprotection relays of this type are typically expected to hold trip timing within a small percentage of the set value - confirm the acceptance tolerance against Wartsila's test procedure or the applicable class requirement

Ranges are typical for this design class. Always confirm against the manufacturer documentation for your serial number.

Critical spares

  • Relay/module unit (like-for-like replacement)
  • Backup battery
  • Terminal/connector blocks

Safety

  • Arc flash and electric shock risk during live testing at the generator switchboard
  • Secondary injection testing must correctly isolate CT circuits - an open-circuit CT is a serious hazard
  • This module is safety-critical - never bypass reverse power or overload protection to keep a generator connected

Class survey

Category mismatch noted above. Class treats generator protection (reverse power, overload, short-circuit) as essential per statutory/class electrical rules; the surveyor will want to witness trip tests and see the approved setting sheet retained onboard matching the relay's actual settings.

Classification

DNV type approval

Listed in the DNV Approval Finder at the time we recorded it. The certificate is issued by DNV, not by us; check its current status at DNV.

CertificateTAA00000F1
Open the certificate at DNV
Need this part?

Request a quote for this model.

Free of charge — send us your request for Wärtsilä Deutschland GmbH equipment. Our team checks it and replies by e-mail.

For marine equipment hardly any maker or authorised dealer will name a price while the vessel is unknown. With the vessel details, availability and price can be settled faster; without them we may have to ask first, which costs a few days. If you are not allowed to name the vessel, a photo of the rating plate is enough — attach it below or send it as a reply to our confirmation e-mail.

Your contact details are not published. No account required.
Related models

Also in Shaft Generator / PTO.

Other models of the same equipment type, Wärtsilä Deutschland GmbH first.

By manufacturer Mecc AlteKongsbergMenzelCaterpillar Marine PowerCumminsZF FriedrichshafenCIFARenkABBD-I IndustrialMTUZF MarineJohn DeereSTAMFORD | AvKTwin DiscAll manufacturersSpare parts by equipmentNew here? Create a free account Can't read the plate? Try the nameplate scanner All Wärtsilä Deutschland GmbH models More like Generator Protection Module, GPM 500, Diesel Protection Module, DPM 500
More than the data sheet shows

We answer by e-mail, never with an automatic reply.

Tell us what you need for this Wärtsilä Deutschland GmbH Generator Protection Module, GPM 500, Diesel Protection Module, DPM 500 — a part, a service call, a second opinion. Are you Wärtsilä Deutschland GmbH? Claim this brand page.

Service engineer? Write the day report for this Generator Protection Module, GPM 500, Diesel Protection Module, DPM 500 in OceanSphere Work — photos, hours and parts, as a PDF for the owner. Try it free for 14 days →

Frequently asked

Questions that come up with this equipment.

Is this model's data free?

Yes. Specifications, documents and service notes for this model are readable without an account. An account adds saved searches and requests, nothing is taken away.

Can you find a part for this exact model?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.

The specifications look wrong — what now?

Send us the nameplate or the correct value. We check it against the manufacturer datasheet or class-society record and update the page.