BFS-10/30/40-N/NE/L-G1/4"...G11/2"-SS/MS-NO/WE-ST by Barksdale GmbH. DNV TA certificate TAA0000204.

Inspector Detail

Common issues

  • Antenna/horn fouling from cargo vapor condensation or product residue
  • False echoes or signal loss from tank internal obstructions (ladders, heating coils)
  • Process connection seal leakage at the tank penetration
  • Electronics/junction box moisture ingress
  • Calibration drift over time, especially after a change of cargo type
  • Cable and connector corrosion in the cargo tank environment

Inspection checklist

  • Visual inspection of antenna/horn for buildup or damage
  • Process connection and gasket/seal leak check
  • Zero/span check against an independent manual ullage reading
  • Junction box and cable gland condition (IP/ex-rating integrity)
  • Cross-check reading against an independent level indication
  • Intrinsic safety barrier and certification check where the unit is hazardous-area rated
  • High/high-high level alarm setpoint verification

Service intervals

Calibration check against manual sounding at each cargo survey or per the SMS schedule
Full function/alarm test per PMS, commonly every 6-12 months
Antenna cleaning condition-based, especially after cargoes prone to residue or vapor buildup

Critical spares

  • Process seal/gasket kit
  • Cable gland set
  • Electronics/junction box module, if the design is modular

Safety

  • This gauge is part of the overflow/high-level alarm chain - an unverified reading is a direct cargo overflow risk
  • Hazardous-area/intrinsically-safe wiring must not be compromised during maintenance
  • Tank access for antenna inspection requires an enclosed-space entry permit

Class survey

Class and PSC check that the independent high-level alarm functions separately from the primary gauge, that the installed unit's TA certificate (TAA0000204) matches the nameplate, and that calibration records are retained on board.

Components & Design

Component data being added…

Technical Data

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

DNV type approval

Verified against the DNV Approval Finder — the certificate below is issued by DNV, not by us.

Certificate
TAA0000204
Open the certificate at DNV →
Equipment Model #52399 · ✓ still in production