Library› Safety & LSA› Fire Detection Systems› Flame Detector› Egon Harig Optical UV-Flame Detector 800/24VST-K-N, 800/24VST-K-NT, 800/24VST-K-M, 800/24VST-K-EW; 800/24VST-K-NT A, 800/24VST-K-EW A
Egon Harig

Optical UV-Flame Detector 800/24VST-K-N, 800/24VST-K-NT, 800/24VST-K-M, 800/24VST-K-EW; 800/24VST-K-NT A, 800/24VST-K-EW A

Flame Detector · Fire Detection Systems

Class-certified type (DNV register) · technical data sheet not yet verified​​⁠​​‌‍⁠​⁠​​‌‌‍​⁠​​‍

Optical UV-Flame Detector 800/24VST-K-N, 800/24VST-K-NT, 800/24VST-K-M, 800/24VST-K-EW; 800/24VST-K-NT A, 800/24VST-K-EW A by Egon Harig GmbH. DNV TA certificate TAA00002F1.

Manufacturer documentation

Images from manufacturer documentation.

Photos, drawings and page previews from this model’s datasheet or catalog.

Optical UV-Flame Detector 800/24VST-K-N, 800/24VST-K-NT, 800/24VST-K-M, 800/24VST-K-EW; 800/24VST-K-NT A, 800/24VST-K-EW A are optical flame detectors for marine applications.Source: 24VST-K-NT, 80, p. 1

Features

  • Alarm sensibility according to EN54 part 10, class 1
  • Potential-free contacts for voltage and failure monitoring
  • Potential-free contacts for fire alarm monitoring
  • Adjustable supervision angle
  • PC-LEXAN 241R housing

Standards

  • IEC 60092-504:2016
  • IEC 60533:2015
  • EN 54-10:2002 incl. A1:2005
Egon Harig Optical UV-Flame Detector 800/24VST-K-N, 800/24VST-K-NT, 800/24VST-K-M, 800/24VST-K-EW; 800/24VST-K-NT A, 800/24VST-K-EW A – Photo (29f89166fe2c_S1-2 S. 1)
Photo · 29f89166fe2c_S1-2 · S. 1
Egon Harig Optical UV-Flame Detector 800/24VST-K-N, 800/24VST-K-NT, 800/24VST-K-M, 800/24VST-K-EW; 800/24VST-K-NT A, 800/24VST-K-EW A – Photo (29f89166fe2c_S1-2 S. 1)
Photo · 29f89166fe2c_S1-2 · S. 1
Egon Harig Optical UV-Flame Detector 800/24VST-K-N, 800/24VST-K-NT, 800/24VST-K-M, 800/24VST-K-EW; 800/24VST-K-NT A, 800/24VST-K-EW A – Drawing (29f89166fe2c_S1-2 S. 1)
Drawing · 29f89166fe2c_S1-2 · S. 1
Egon Harig Optical UV-Flame Detector 800/24VST-K-N, 800/24VST-K-NT, 800/24VST-K-M, 800/24VST-K-EW; 800/24VST-K-NT A, 800/24VST-K-EW A – Drawing (29f89166fe2c_S1-2 S. 2)
Drawing · 29f89166fe2c_S1-2 · S. 2
Source: 24VST-K-NT, 80, p. 2
Classification

DNV type approval

Listed in the DNV Approval Finder at the time we recorded it. The certificate is issued by DNV, not by us; check its current status at DNV.

CertificateTAA00002F1
Open the certificate at DNV
Need this part?

Request a quote for this model.

Free of charge — send us your request for Egon Harig equipment. Our team checks it and replies by e-mail.

For marine equipment hardly any maker or authorised dealer will name a price while the vessel is unknown. With the vessel details, availability and price can be settled faster; without them we may have to ask first, which costs a few days. If you are not allowed to name the vessel, a photo of the rating plate is enough — attach it below or send it as a reply to our confirmation e-mail.

Your contact details are not published. No account required.
Related models

Also in Flame Detector.

Other models of the same equipment type, Egon Harig first.

By manufacturer AutronicaDet-TronicsEgon HarigTyco Fire & SecurityConsiliumApollo Fire DetectorsConsilium SafetyGeneral MonitorsHochiki MarineConsilium Marine & SafetyDrägerEsser / HoneywellFikeNotifier / HoneywellRosemount Inc.All manufacturersSpare parts by equipmentNew here? Create a free account Can't read the plate? Try the nameplate scanner More like Optical UV-Flame Detector 800/24VST-K-N, 800/24VST-K-NT, 800/24VST-K-M, 800/24VST-K-EW; 800/24VST-K-NT A, 800/24VST-K-EW A
More than the data sheet shows

We answer by e-mail, never with an automatic reply.

Tell us what you need for this Egon Harig Optical UV-Flame Detector 800/24VST-K-N, 800/24VST-K-NT, 800/24VST-K-M, 800/24VST-K-EW; 800/24VST-K-NT A, 800/24VST-K-EW A — a part, a service call, a second opinion. Are you Egon Harig? Claim this brand page.

Service engineer? Write the day report for this Optical UV-Flame Detector 800/24VST-K-N, 800/24VST-K-NT, 800/24VST-K-M, 800/24VST-K-EW; 800/24VST-K-NT A, 800/24VST-K-EW A in OceanSphere Work — photos, hours and parts, as a PDF for the owner. Try it free for 14 days →

Frequently asked

Questions that come up with this equipment.

Is this model's data free?

Yes. Specifications, documents and service notes for this model are readable without an account. An account adds saved searches and requests, nothing is taken away.

Can you find a part for this exact model?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.

The specifications look wrong — what now?

Send us the nameplate or the correct value. We check it against the manufacturer datasheet or class-society record and update the page.