B50AGe Type Class B-15 Bulkhead
B50AGe Type Class B-15 Bulkhead by Huanan Building Materials (Shenzhen) Co., Ltd.. DNV MED certificate MEDB00001EB.
Inspector Detail
▸
Common issues
- Panel joints and seams not sealed per the approved installation drawing, breaking fire/smoke integrity at the seam
- Incorrect stud or frame spacing during installation, reducing structural and fire performance
- Panel face damage (dents, punctures) from later outfitting work exposing or compressing the core material
- Missing or paint-clogged intumescent seals at door frames set within the bulkhead
- Moisture ingress at deckhead or floor penetrations degrading the panel core over time
- Unauthorized cable or pipe penetrations made without restoring the certified fire rating
- Panel damage hidden under later paint or insulation, missed during routine visual rounds
Inspection checklist
- Verify the panel type-approval marking is present and legible
- Check all joints and seams for continuous sealing per the approved installation drawing
- Inspect panel faces for dents, punctures or delamination
- Confirm all cable/pipe penetrations are fitted with approved fire-rated stops
- Check door and frame intumescent seals for damage or paint-over
- Verify no unauthorized structural penetrations have been made since the last survey
- Inspect for signs of moisture ingress or core degradation (bulging, discoloration, soft spots)
- Confirm the bulkhead is correctly identified on the fire control plan
Service intervals
| Visual condition survey | annually, as part of fire safety rounds |
| Joint and seal condition check | at each dry-docking |
| Fire control plan cross-check | at each renewal survey |
Typical wear limits
| Panel face puncture | any through-puncture of the facing sheet is normally not acceptable and requires repair - confirm against class guidance for a B-15 division |
| Joint gap after installation | should be fully sealed with no visible gap - confirm against the approved drawing tolerance |
Ranges are typical for this design class. Always confirm against the manufacturer documentation for your serial number.
Critical spares
- Matching panel sections of the same type-approved B-15 product for repair
- Approved joint sealant or sealing strip
- Intumescent door seals
- Fire-rated cable/pipe penetration stops compatible with this panel system
Safety
- Any unsealed penetration or damaged panel reduces the fire/smoke integrity of the division - report and rectify without delay, do not defer to next dry-dock
- Do not hot-work near the panel without confirming the core material's fire behaviour and obtaining a permit
- Keep escape routes and doors within the division clear and closing correctly - fire integrity defects often coincide with obstructed egress in the same space
Class survey
Surveyors check that the fire control plan matches the as-built division, that penetrations are properly stopped, and that panel condition has not been compromised by later outfitting work. B-class divisions are normally checked during fire safety rounds and at renewal survey.
Components & Design
Component data being added…
Technical Data
🤖 Ask about this model
One free question — answered like a marine engineer. No account needed.
Suppliers & Spare Parts
Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.
📄 Request sourcing links & documentsCases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.
Start free trial →Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.
Maritime Network →DNV type approval
Verified against the DNV Approval Finder — the certificate below is issued by DNV, not by us.
- Certificate
- MEDB00001EB