A-60 Deck with Rockfibras PNR-128 insulation
A-60 Deck with Rockfibras PNR-128 insulation by Rockfibras do Brasil Industria e Comercio Ltda. DNV MED certificate MEDB000033V.
Inspector Detail
▸
Common issues
- Insulation compression or displacement from foot traffic/stowage against deck insulation without protection
- Moisture ingress into the mineral wool insulation reducing thermal/fire performance
- Fixing pin/clip corrosion allowing insulation to sag away from the deck
- Vapour barrier damage leading to condensation within the insulation package
- Unauthorized penetrations breaking A-60 continuity
- Facing/cladding damage exposing insulation to mechanical damage
Inspection checklist
- Visual check of insulation cladding/facing for damage or displacement
- Check fixing pins/clips are intact and insulation is firmly secured to the deck
- Inspect for moisture staining indicating vapour barrier failure
- Verify no unauthorized penetrations exist without an approved fire-stop detail
- Check insulation thickness/coverage is maintained at deck penetrations, stiffeners and edges
- Confirm certification/type approval marking is traceable to the fire control plan
Service intervals
| Visual condition survey | at each annual/intermediate class survey |
| Fixing/cladding repair | on condition, whenever damage is found |
Critical spares
- Matching certified mineral wool insulation of the same type as installed, per the panel manufacturer's specification
- Facing/cladding material matching the original certificate
- Fixing pins/clips and vapour barrier material of the approved type
Safety
- Any breach or uncertified repair can compromise the A-60 deck fire division rating - treat as a fire safety deficiency until restored
- Mineral wool fibres are an irritant - use appropriate PPE when handling during repair
- Do not penetrate without an approved fire-stop detail for the specific penetration
Class survey
Checked as part of fire division integrity surveys under class/SOLAS II-2: surveyors confirm the A-60 deck insulation matches the approved fire control plan, that penetrations are properly fire-stopped, and that any repairs use insulation and cladding covered by an equivalent type approval.
Components & Design
Component data being added…
Technical Data
🤖 Ask about this model
One free question — answered like a marine engineer. No account needed.
Suppliers & Spare Parts
Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.
📄 Request sourcing links & documentsCases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.
Start free trial →Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.
Maritime Network →DNV type approval
Verified against the DNV Approval Finder — the certificate below is issued by DNV, not by us.
- Certificate
- MEDB000033V
- Approved as
- A & B Class divisions fire integrity: A class divisions.
- Certificate holder
- Rockfibras do Brasil Industria e Comercio Ltda (Brazil)
- Valid until
- 2028-05-09