Rockfibras do Brasil Industria e Comercio Ltda

A-60 Deck with Rockfibras PNR-128 insulation

A-60 Deck with Rockfibras PNR-128 insulation by Rockfibras do Brasil Industria e Comercio Ltda. DNV MED certificate MEDB000033V.

Inspector Detail

Common issues

  • Insulation compression or displacement from foot traffic/stowage against deck insulation without protection
  • Moisture ingress into the mineral wool insulation reducing thermal/fire performance
  • Fixing pin/clip corrosion allowing insulation to sag away from the deck
  • Vapour barrier damage leading to condensation within the insulation package
  • Unauthorized penetrations breaking A-60 continuity
  • Facing/cladding damage exposing insulation to mechanical damage

Inspection checklist

  • Visual check of insulation cladding/facing for damage or displacement
  • Check fixing pins/clips are intact and insulation is firmly secured to the deck
  • Inspect for moisture staining indicating vapour barrier failure
  • Verify no unauthorized penetrations exist without an approved fire-stop detail
  • Check insulation thickness/coverage is maintained at deck penetrations, stiffeners and edges
  • Confirm certification/type approval marking is traceable to the fire control plan

Service intervals

Visual condition survey at each annual/intermediate class survey
Fixing/cladding repair on condition, whenever damage is found

Critical spares

  • Matching certified mineral wool insulation of the same type as installed, per the panel manufacturer's specification
  • Facing/cladding material matching the original certificate
  • Fixing pins/clips and vapour barrier material of the approved type

Safety

  • Any breach or uncertified repair can compromise the A-60 deck fire division rating - treat as a fire safety deficiency until restored
  • Mineral wool fibres are an irritant - use appropriate PPE when handling during repair
  • Do not penetrate without an approved fire-stop detail for the specific penetration

Class survey

Checked as part of fire division integrity surveys under class/SOLAS II-2: surveyors confirm the A-60 deck insulation matches the approved fire control plan, that penetrations are properly fire-stopped, and that any repairs use insulation and cladding covered by an equivalent type approval.

Estimated lifetime: Not applicable in running hours - passive fire insulation is expected to last the structural life of the deck if undamaged, moisture-free and unmodified.

Components & Design

Component data being added…

Technical Data

imo approved True

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

DNV type approval

Verified against the DNV Approval Finder — the certificate below is issued by DNV, not by us.

Certificate
MEDB000033V
Approved as
A & B Class divisions fire integrity: A class divisions.
Valid until
2028-05-09
Open the certificate at DNV →
Equipment Model #42305 · ✓ still in production