Specifications

Technical data.

Do you have the manufacturer datasheet for this model? Send it with the enquiry form — we check it and name the source.

IMO ApprovedYes
Inspection

Inspector Detail

Common issues

  • Nozzle/seat wear affecting spray pattern and shut-off tightness
  • Seized or stiff manual/remote operating mechanism from corrosion or lack of exercise
  • Packing/seal leakage at the swivel joints
  • Corrosion of the monitor body and mounting base in the exposed weather deck location
  • Foam concentrate induction/eductor fouling or incorrect proportioning
  • Remote control actuator failure on remote-operated monitors
  • Blocked strainer reducing flow

Inspection checklist

  • Function-test monitor rotation (horizontal/vertical) and nozzle pattern change (jet/spray)
  • Check free movement of all swivel joints
  • Visually check the body and base for corrosion or damage
  • Verify foam concentrate proportioning rate where applicable
  • Check remote control operation from the control station, if fitted
  • Check the strainer/inlet for blockage
  • Verify flow and pressure against the design rating
  • Check mounting bolts and deck penetration sealing
  • Confirm identification and coverage signage is in place

Service intervals

Function testat weekly/monthly fire drill routine per the vessel's fire safety maintenance plan
Full flow test with foam concentratecommonly annually, per maker/class requirement
Swivel joint lubricationper maker's schedule
Remote actuator inspectionat annual fire safety survey

Typical intervals for this design class, not the manufacturer’s figures for your model. The manufacturer’s manual is binding.

Critical spares

  • Nozzle assembly
  • Swivel joint seal/packing kit
  • Strainer element
  • Remote actuator seal kit (for remote-operated units)

Safety

  • High-momentum jet/spray discharge - secure the monitor and clear personnel from the discharge arc before testing
  • Foam concentrate is a slip hazard on deck
  • Pressurized firemain supply
  • Moving parts (rotation/elevation) can pinch fingers during manual or remote operation
  • Working at height at some monitor mounting locations

Class survey

This unit's marine equipment database category on this listing is recorded as an addressable fire detection panel, which does not match its description as a foam/water monitor - a mechanical discharge device, not detection electronics. Please verify and correct the category before publishing. Fixed foam/water monitors are part of the fire-fighting system reviewed at fire safety survey; class checks function testing records, foam concentrate proportioning performance, and that monitor coverage matches the approved fire control plan.

Estimated lifetime: As fixed fire-fighting deck equipment rather than continuously running machinery, service life is governed by corrosion condition and periodic function/flow testing rather than running hours; the maker's guidance and class/flag survey findings determine replacement timing.

Classification

DNV type approval

Listed in the DNV Approval Finder at the time we recorded it. The certificate is issued by DNV, not by us; check its current status at DNV.

CertificateMEDB0000184
Open the certificate at DNV
Need this part?

Request a quote for this model.

Free of charge — send us your request for SURVITEC Fire Solution Poland Sp. z o.o. equipment. Our team checks it and replies by e-mail.

For marine equipment hardly any maker or authorised dealer will name a price while the vessel is unknown. With the vessel details, availability and price can be settled faster; without them we may have to ask first, which costs a few days. If you are not allowed to name the vessel, a photo of the rating plate is enough — attach it below or send it as a reply to our confirmation e-mail.

Your contact details are not published. No account required.
Related models

Also in Addressable Fire Detection Panel.

Other models of the same equipment type, SURVITEC Fire Solution Poland Sp. z o.o. first.

By manufacturer AutronicaConsiliumSiemens Fire SafetyNotifier / HoneywellHochikiEsser / HoneywellApollo MarineThermal Ceramics UKZhejiang Winner Fire Fighting Equipment Co., LtdBIO-EXEkornes ASBrødrene AA ASCBG Systems InternationalDELIUS GmbH & Co. KGGRUPPO MASTROTTO S.p.A.All manufacturersSpare parts by equipmentNew here? Create a free account Can't read the plate? Try the nameplate scanner More like Foam/Water Monitors Type: UFM-80M, UFM-100M, UFM-150M, UFM-80H, UFM-100H
More than the data sheet shows

We answer by e-mail, never with an automatic reply.

Tell us what you need for this SURVITEC Fire Solution Poland Sp. z o.o. Foam/Water Monitors Type: UFM-80M, UFM-100M, UFM-150M, UFM-80H, UFM-100H — a part, a service call, a second opinion. Are you SURVITEC Fire Solution Poland Sp. z o.o.? Claim this brand page.

Service engineer? Write the day report for this Foam/Water Monitors Type: UFM-80M, UFM-100M, UFM-150M, UFM-80H, UFM-100H in OceanSphere Work — photos, hours and parts, as a PDF for the owner. Try it free for 14 days →

Frequently asked

Questions that come up with this equipment.

Is this model's data free?

Yes. Specifications, documents and service notes for this model are readable without an account. An account adds saved searches and requests, nothing is taken away.

Can you find a part for this exact model?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.

The specifications look wrong — what now?

Send us the nameplate or the correct value. We check it against the manufacturer datasheet or class-society record and update the page.