Library› Engine Room› Oily Water & Waste Systems› Sewage Treatment Plant› Wartsila Water Systems Ltd. SUPER TRIDENT Sewage Treatment models: STC0-23, STC01-13, STC02-13, STC03-13, STC04-13, STC06-13, STC08-14, STC10-14, STC13-14, STC15-14, STC20-14, STC25-14, STC30-14, STC40-14, STC50-14, STC60-14, RTC20-14, RTC40-14, RTC60-14, RTC80-14

SUPER TRIDENT Sewage Treatment models: STC0-23, STC01-13, STC02-13, STC03-13, STC04-13, STC06-13, STC08-14, STC10-14, STC13-14, STC15-14, STC20-14, STC25-14, STC30-14, STC40-14, STC50-14, STC60-14, RTC20-14, RTC40-14, RTC60-14, RTC80-14

Sewage Treatment Plant · Oily Water & Waste Systems

Class-certified type (DNV register) · technical data sheet not yet verified​​‍‍​‌‍‍‌⁠⁠⁠‌‌​‌​‌‌​

SUPER TRIDENT Sewage Treatment models: STC0-23, STC01-13, STC02-13, STC03-13, STC04-13, STC06-13, STC08-14, STC10-14, STC13-14, STC15-14, STC20-14, STC25-14, STC30-14, STC40-14, STC50-14, STC60-14, RTC20-14, RTC40-14, RTC60-14, RTC80-14 by Wartsila Water Systems Ltd. DNV MED certificate MEDB00008RD.

Specifications

Technical data.

Do you have the manufacturer datasheet for this model? Send it with the enquiry form — we check it and name the source.

IMO ApprovedYes
Inspection

Inspector Detail

Common issues

  • Aeration blower failure or diffuser fouling reducing treatment efficiency
  • Macerator/comminutor blockage from foreign objects (rags, wipes) entering the sewage line
  • Disinfection cell/electrode scaling reducing residual disinfectant output on electrochlorination models
  • Effluent quality drifting outside MARPOL Annex IV discharge limits when the unit is overloaded beyond rated capacity
  • Level sensor or float switch fouling causing pump short-cycling or tank overflow
  • Discharge/transfer pump wear from solids in the sewage stream
  • Odour complaints from inadequate venting or a faulty air scrubber
  • Control panel/PLC faults on the larger, more automated models in this range

Inspection checklist

  • Verify the current MEPC/IMO Type Approval certificate matches the installed model designation exactly
  • Check effluent samples against MARPOL Annex IV limits where a test kit or shore analysis is available
  • Inspect aeration blower operation and diffuser condition
  • Check the macerator/comminutor for blockage and blade wear
  • Inspect the disinfection system (electrochlorination cell or UV lamp, depending on model)
  • Check all pumps for correct operation with no abnormal noise or vibration
  • Inspect accessible tank internals for solids build-up or sludge accumulation
  • Verify level alarms and high-level overflow protection function correctly
  • Check the vent line and any odour control equipment
  • Confirm the discharge/overboard valve arrangement complies with MARPOL requirements (sealed/locked where required)

Service intervals

Aeration blower serviceannually per manufacturer's schedule; check belt/bearing condition every 3-6 months
Macerator blade inspectionevery 3-6 months, or sooner if flow is reduced
Disinfection cell/electrode cleaning (electrochlorination models)every 3-6 months, more often with poor water quality
Effluent sampling for MARPOL complianceper flag state/PSC requirement, typically annually or at survey
Sludge/tank inspection and cleaningannually or per manufacturer's recommendation

Typical intervals for this design class, not the manufacturer’s figures for your model. The manufacturer’s manual is binding.

Typical wear limits

Macerator blade clearanceper the manufacturer's manual for this specific model - inspect for excessive gap causing incomplete maceration
Effluent BOD / TSS / coliform countmust stay within the MARPOL Annex IV Type Approval limits for the unit; any sustained drift above certificate values means the plant needs service

Ranges are typical for this design class. Always confirm against the manufacturer documentation for your serial number.

Critical spares

  • Macerator/comminutor blades and seals
  • Aeration blower diaphragm/bearing kit
  • Disinfection cell electrodes or UV lamp (model-dependent)
  • Pump impeller and mechanical seal kits
  • Level float switches/sensors
  • Control panel fuses and relays

Safety

  • Sewage systems present a biological hazard - use appropriate PPE and hygiene procedures whenever the system is opened
  • Confined space entry precautions apply if internal tank inspection is required
  • Chlorine gas risk on electrolytic/chemical disinfection variants - ensure ventilation and follow the manufacturer's handling procedure
  • Isolate electrical power before servicing blowers, pumps, or the control panel
  • Trapped gas pockets are possible in sludge/solids - test the atmosphere before opening any sealed compartment

Class survey

Note: this record is filed under the category 'Vacuum Toilet System' but the actual product is a biological/chemical sewage treatment plant, not a vacuum toilet unit - the content above addresses the treatment plant. Sewage treatment plants fall under MARPOL Annex IV survey requirements; class/flag state checks that the Type Approval certificate matches the installed unit and may request effluent quality records. This product line covers many capacity variants (STC0-23 through RTC80-14) - confirm the exact model against the nameplate and certificate, as internal components and capacity differ across the range.

Classification

DNV type approval

Listed in the DNV Approval Finder at the time we recorded it. The certificate is issued by DNV, not by us; check its current status at DNV.

CertificateMEDB00008RD
Open the certificate at DNV
Need this part?

Request a quote for this model.

Free of charge — send us your request for Wartsila Water Systems Ltd. equipment. Our team checks it and replies by e-mail.

For marine equipment hardly any maker or authorised dealer will name a price while the vessel is unknown. With the vessel details, availability and price can be settled faster; without them we may have to ask first, which costs a few days. If you are not allowed to name the vessel, a photo of the rating plate is enough — attach it below or send it as a reply to our confirmation e-mail.

Your contact details are not published. No account required.
Related models

Also in Sewage Treatment Plant.

Other models of the same equipment type, Wartsila Water Systems Ltd. first.

Wartsila Water Systems Ltd.
Enhanced Super Trident (STC01-13)
Wartsila Water Systems Ltd.
MBR2, MBR4, MBR6, MBR8, MBR12, MBR16, MBR18, MBR24, MBR30, MBR32, MBR36, MBR40, MBR42, MBR48, MBR54, MBR56, MBR60, MBR64
Wartsila Water Systems Ltd.
STC0-23, STC01-13, STC02-13, STC03-13, STC04-13, STC06-13, STC08-14, STC10-14, STC13-14, STC15-14, STC20-14, STC25-14, STC30-14, STC40-14, STC50-14, STC60-14, RTC20-14, RTC40-14, RTC60-14, RTC80-14
Wartsila Water Systems Ltd.
Sewage systems (for use by passenger ships in all areas, including a MARPOL Annex IV special area (MBR16-G0099353)
Wartsila Water Systems Ltd.
Sewage systems (for use by passenger ships in all areas, including a MARPOL Annex IV special area). (MBR16 GO099464)
Wartsila Water Systems Ltd.
Sewage systems (for use by passenger ships in all areas, including a MARPOL Annex IV special area). (MBR24 GO099674)
Wartsila Water Systems Ltd.
Sewage systems (for use by ships, other than passenger ships, in all areas and by passenger ships outside MARPOL Annex IV special areas). (MBR16 GO099742)
Wartsila Water Systems Ltd.
Sewage systems (for use by ships, other than passenger ships, in all areas and by passenger ships outside MARPOL Annex IV special areas). (RTC20-14, RTC40-14, RTC60-14 and RTC80-14)
Wartsila Water Systems Ltd.
Sewage systems (for use by ships, other than passenger ships, in all areas and by passenger ships outside MARPOL Annex IV special areas). (STC0-23)
Wartsila Water Systems Ltd.
Sewage systems (for use by ships, other than passenger ships, in all areas and by passenger ships outside MARPOL Annex IV special areas). (STC02-13, STC03-13, STC04-13 and STC06-13)
By manufacturer EvacWärtsiläACO MarineTecnicomarJowaHamannVictor MarineScience Nature Technology (SNT)DetegasaDVZHanla IMSScienco/FAST, Bio-Microbics, Inc.GERTSEN & OLUFSENRWOGROCOAll manufacturersSpare parts by equipmentNew here? Create a free account Can't read the plate? Try the nameplate scanner All Wartsila Water Systems Ltd. models More like SUPER TRIDENT Sewage Treatment models: STC0-23, STC01-13, STC02-13, STC03-13, STC04-13, STC06-13, STC08-14, STC10-14, STC13-14, STC15-14, STC20-14, STC25-14, STC30-14, STC40-14, STC50-14, STC60-14, RTC20-14, RTC40-14, RTC60-14, RTC80-14
More than the data sheet shows

We answer by e-mail, never with an automatic reply.

Tell us what you need for this Wartsila Water Systems Ltd. SUPER TRIDENT Sewage Treatment models: STC0-23, STC01-13, STC02-13, STC03-13, STC04-13, STC06-13, STC08-14, STC10-14, STC13-14, STC15-14, STC20-14, STC25-14, STC30-14, STC40-14, STC50-14, STC60-14, RTC20-14, RTC40-14, RTC60-14, RTC80-14 — a part, a service call, a second opinion. Are you Wartsila Water Systems Ltd.? Claim this brand page.

Service engineer? Write the day report for this SUPER TRIDENT Sewage Treatment models: STC0-23, STC01-13, STC02-13, STC03-13, STC04-13, STC06-13, STC08-14, STC10-14, STC13-14, STC15-14, STC20-14, STC25-14, STC30-14, STC40-14, STC50-14, STC60-14, RTC20-14, RTC40-14, RTC60-14, RTC80-14 in OceanSphere Work — photos, hours and parts, as a PDF for the owner. Try it free for 14 days →

Frequently asked

Questions that come up with this equipment.

Is this model's data free?

Yes. Specifications, documents and service notes for this model are readable without an account. An account adds saved searches and requests, nothing is taken away.

Can you find a part for this exact model?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.

The specifications look wrong — what now?

Send us the nameplate or the correct value. We check it against the manufacturer datasheet or class-society record and update the page.