TEFROcor 150 SW-SC
TEFROcor 150 SW-SC by G. Theodor Freese GmbH. DNV MED certificate MEDB00006WE.
Inspector Detail
▸
Common issues
- Panel joint sealant/tape degradation over time, reducing the continuity of the fire/smoke boundary
- Surface delamination or facing damage from mechanical impact or prolonged moisture exposure
- Fixing/fastener corrosion in wet-space installations (bathrooms, galleys)
- Discolouration or facing damage from UV exposure near windows/skylights
- Loss of certified fire classification if panels are drilled or penetrated without maker-approved methods
- Core degradation if the panel facing is breached and moisture ingresses
Inspection checklist
- Visual inspection of panel surfaces and joints for damage, delamination, or moisture staining
- Check that any penetrations (cable/pipe runs) use maker-approved sealing methods to preserve fire rating
- Inspect fixings and edge trims for corrosion or looseness
- Confirm panels retain legible type approval/fire class marking where required
- Check for unauthorised modifications (extra holes, unapproved coatings) that could affect certified fire performance
Service intervals
| General condition inspection | at each internal survey/maintenance round, typically annually |
| Joint sealant/tape condition check | per SMS planned maintenance, typically every 1-2 years |
Critical spares
- Replacement panel sections (correct type/thickness as certified)
- Maker-approved joint sealant/tape
- Edge trims and fixings
Safety
- Do not modify, drill, or coat MED type-approved interior/fire panels with non-approved materials - this can invalidate the certified fire performance
- Damaged panels in fire-rated divisions should be reported and repaired using maker-approved methods to maintain the division's rating
- Follow the maker's data sheet when cutting, drilling, or handling panels - some core/facing materials require dust and edge precautions
Class survey
MED type-approved interior/construction materials (fire-rated divisions, linings) are checked at survey for continued integrity of fire-rated divisions, correct/legible type approval marking matching the certificate (MEDB00006WE), and absence of unauthorised penetrations or modifications that could compromise certified fire performance. Limited manufacturer-specific technical detail is available for this exact product (TEFROcor 150 SW-SC) beyond its MED certificate scope, so content above is kept to bauart-general marine interior panel guidance rather than product-specific claims.
Components & Design
Component data being added…
Technical Data
🤖 Ask about this model
One free question — answered like a marine engineer. No account needed.
Suppliers & Spare Parts
Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.
📄 Request sourcing links & documentsCases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.
Start free trial →Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.
Maritime Network →DNV type approval
Verified against the DNV Approval Finder — the certificate below is issued by DNV, not by us.
- Certificate
- MEDB00006WE
- Approved as
- Surface materials and floor coverings with low flame-spread characteristics: paint systems
- Certificate holder
- G. Theodor Freese GmbH (Germany)
- Valid until
- 2029-07-04