Library› Engine Room› Miscellaneous Approvals› DNV Type Approval (unclassified)› Hydraulic Systems S.r.l. Certificate MEDD00002J7
Hydraulic Systems S.r.l.

MED type-approval certificate MEDD00002J7

DNV Type Approval (unclassified) · Miscellaneous Approvals

Class-certified type (DNV register) · technical data sheet not yet verified​​‍‍​​‌⁠⁠⁠‍‌​‍‌​‌‌‌​

Certificate MEDD00002J7 by Hydraulic Systems S.r.l. DNV MED certificate MEDD00002J7.

Specifications

Technical data.

Do you have the manufacturer datasheet for this model? Send it with the enquiry form — we check it and name the source.

IMO ApprovedYes
Inspection

Inspector Detail

Common issues

  • Hydraulic oil contamination or moisture ingress causing directional valve sticking
  • Vane seal wear leading to internal leakage and reduced rudder torque
  • Rudder stock seal/gland leakage
  • Relief valve set-pressure drift affecting maximum torque
  • Follow-up (feedback) unit misalignment causing rudder angle indication error
  • Air entrainment in the hydraulic system causing spongy or erratic rudder response
  • Non-return/isolating valve wear allowing cross-flow between pumps

Inspection checklist

  • Daily pre-departure test of changeover between power units (SOLAS)
  • Weekly emergency steering gear operation test
  • Hydraulic oil level, colour and water-content check
  • Rudder angle indicator accuracy check against actual rudder position
  • Vane seal leak-off/drain inspection for excessive oil loss
  • Relief valve set pressure check against maker specification
  • Rudder stock gland/seal leakage inspection
  • Alarm function test (low oil level, phase failure, overload)
  • Mounting bolts and stock coupling looseness check
  • Full rudder angle/response time check against the SOLAS 28-second requirement

Service intervals

Hydraulic oil sampling/analysisevery 6-12 months
Full oil changetypically every 2-5 years or on condition
Vane seal inspection/renewalcondition-based, typically reviewed at dry-docking
Relief valve calibration checkannual
Rudder stock seal inspectionat dry-docking
Changeover/emergency steering drillweekly per SOLAS

Typical intervals for this design class, not the manufacturer’s figures for your model. The manufacturer’s manual is binding.

Typical wear limits

Rudder stock coupling bolt clearancere-fit/renew per the maker's tolerance - confirm against the maker manual, no generic figure applies
Vane-to-housing clearanceassessed by leakage/pressure-drop trend rather than a fixed dimension on most rotary vane designs - confirm against the maker manual

Ranges are typical for this design class. Always confirm against the manufacturer documentation for your serial number.

Critical spares

  • Vane seal set
  • Rudder stock seal/gland packing
  • Relief valve
  • Hydraulic pump shaft seal
  • Non-return valve
  • Follow-up unit sensor/potentiometer
  • Power-unit selector solenoid valve

Safety

  • High-pressure hydraulic oil injection injury risk during leak-tracing or seal work
  • Entrapment/crush hazard from rudder movement during testing - lock out before working in the steering flat
  • Loss-of-steering risk during changeover testing - coordinate with the bridge before isolating any unit
  • Stored energy in an accumulator, if fitted - depressurize before maintenance

Class survey

Statutory item under SOLAS Ch. II-1 and a class survey item: annual test of main and auxiliary/emergency steering, and a 5-yearly opening-up survey are typical, with documented changeover-drill and relief-valve/alarm test records expected at each annual survey.

Estimated lifetime: Rotary vane steering gear is generally designed for the vessel's full service life (20-25 years) with seals and wear parts renewed at survey intervals; the vane housing and rotor itself is rarely a wear-out item under normal operation.

Classification

DNV type approval

Listed in the DNV Approval Finder at the time we recorded it. The certificate is issued by DNV, not by us; check its current status at DNV.

CertificateMEDD00002J7
Open the certificate at DNV
Need this part?

Request a quote for this model.

Free of charge — send us your request for Hydraulic Systems S.r.l. equipment. Our team checks it and replies by e-mail.

For marine equipment hardly any maker or authorised dealer will name a price while the vessel is unknown. With the vessel details, availability and price can be settled faster; without them we may have to ask first, which costs a few days. If you are not allowed to name the vessel, a photo of the rating plate is enough — attach it below or send it as a reply to our confirmation e-mail.

Your contact details are not published. No account required.
Related models

Also in DNV Type Approval (unclassified).

Other models of the same equipment type.

By manufacturer FMC Technologies Inc. - Fluid ControlAlfa Laval Qingdao Ltd.Jiujiang Gongchuang Machinery Equipment Co., Ltd.Bay Valves ApSMMC (Asia) LimitedPackard InternationalVEGA GrieshaberVentiq ASDril-Quip, Inc.Manuli Hydraulics ManufacturingShanghai Siaco New Materials Technology Co., Ltd.SRI Energy Inc.The Oilgear CompanyA-Plus Engineering CompanyAlfagomma HydraulicAll manufacturersSpare parts by equipmentNew here? Create a free account Can't read the plate? Try the nameplate scanner More like Certificate MEDD00002J7
More than the data sheet shows

We answer by e-mail, never with an automatic reply.

Tell us what you need for this Hydraulic Systems S.r.l. Certificate MEDD00002J7 — a part, a service call, a second opinion. Are you Hydraulic Systems S.r.l.? Claim this brand page.

Service engineer? Write the day report for this Certificate MEDD00002J7 in OceanSphere Work — photos, hours and parts, as a PDF for the owner. Try it free for 14 days →

Frequently asked

Questions that come up with this equipment.

Is this model's data free?

Yes. Specifications, documents and service notes for this model are readable without an account. An account adds saved searches and requests, nothing is taken away.

Can you find a part for this exact model?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.

The specifications look wrong — what now?

Send us the nameplate or the correct value. We check it against the manufacturer datasheet or class-society record and update the page.