"> Draeger Safety UK Limited Draeger Lifeline - 3362313
⚓ Working on this equipment?
Ask the AI troubleshooter, log your hours on board and turn them into invoice-ready service reports — for this exact model.
Start free — 14 days →
No credit card required
🔧 1 verified suppliers & service companies for Draeger Safety UK Limited in the Maritime Network Find suppliers →
Draeger Safety UK Limited

Draeger Lifeline - 3362313

Draeger Lifeline - 3362313 by Draeger Safety UK Limited. DNV MED certificate MEDB00006SV.

Inspector Detail

Common issues

  • Coupling corrosion or thread damage preventing a secure connection
  • Hose fabric or lining degradation (rot, UV or chemical damage) leading to leaks or burst under pressure
  • Gasket/washer deterioration at couplings causing leakage
  • Kinking or abrasion damage from improper stowage or flaking
  • Mold/mildew growth if stowed wet
  • Coupling-to-hose bond failure (pull-off) under pressure

Inspection checklist

  • Visual inspection for cuts, abrasion, mildew and discoloration along the full hose length
  • Check couplings for corrosion, thread damage, and a secure fit to hydrant and nozzle
  • Confirm a serviceable gasket/washer is present at each coupling
  • Confirm the hose is correctly flaked and stowed in its box or on the reel per drill routine
  • Pressure test per the flag-state/maker schedule - unroll, connect, pressurize, inspect for leaks or bulging
  • Verify hose length and diameter match the fire control plan for that station
  • Check nozzle operation (jet/spray, shut-off) at each drill

Service intervals

Visual inspection monthly as part of routine fire safety rounds
Pressure test per the SOLAS/flag-state fire hose testing schedule, commonly annually
Full unroll and reflake at fire drills, per the SOLAS drill frequency (monthly)
Replacement condition-based, or per the manufacturer's stated service life where specified - confirm against Draeger documentation

Typical wear limits

Coupling gasket condition replace when hardened, cracked, or no longer providing a leak-tight seal at test pressure - condition-based, not a fixed lifespan

Ranges are typical for this design class. Always confirm against the manufacturer documentation for your serial number.

Critical spares

  • Replacement coupling gaskets/washers
  • Spare hose lengths matching the station's specified diameter, length and coupling type
  • Spare nozzle where applicable

Safety

  • A hose under pressure can whip if a coupling fails or the hose bursts - stand clear and secure before charging
  • Couplings can be heavy - back/foot injury risk when handling
  • Do not use fire hoses for non-fire purposes, as this masks wear that could cause failure in an emergency

Class survey

Fire hoses are SOLAS firefighting equipment subject to the vessel's fire control plan (correct number, length and location) and periodic testing under the flag state's/RO's fire safety inspection regime. The MED type-approval evidenced here confirms design/construction compliance at supply; ongoing compliance is verified through the ship's fire drill and equipment inspection records, checked by surveyors at annual and renewal surveys.

Components & Design

Component data being added…

Technical Data

imo approved True

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

DNV type approval

Verified against the DNV Approval Finder — the certificate below is issued by DNV, not by us.

Certificate
MEDB00006SV
Approved as
Fire-fighters outfit – lifeline:- lifelines for breathing apparatus approved under item MED/3.7 and item MED/7.1
Certificate holder
Draeger Safety UK Limited (United Kingdom of Great Britain and Northern Ireland)
Valid until
2030-07-20
Open the certificate at DNV →
Equipment Model #39910 · ✓ still in production