Inspector Detail

Common issues

  • Hose fabric/lining degradation (dry rot, UV damage) from prolonged storage or weather exposure
  • Coupling corrosion or thread damage preventing proper connection to hydrants or nozzles
  • Internal lining delamination or cracking causing leaks under pressure
  • Mildew growth in hoses stowed wet
  • Physical damage (cuts, abrasion) from careless deployment or storage
  • Gasket/washer deterioration at couplings causing leaks

Inspection checklist

  • Visual inspection for external damage, abrasion and UV degradation
  • Pressure test at rated working pressure per the manufacturer/flag requirement
  • Check coupling threads and gaskets for damage, corrosion, correct fit to hydrants and nozzles
  • Confirm the hose is correctly rolled/stowed and readily accessible
  • Check hose length and marking against the fire control plan
  • Verify hose reel or rack mechanism operates freely where fitted

Service intervals

Visual inspection monthly, as part of fire equipment rounds
Pressure test annually, or per flag state requirement
Full replacement bauart-typical 8-10 years or per the manufacturer's stated service life, or immediately on failing a pressure test

Typical wear limits

Proof/working pressure test to the pressure stated on the hose/manufacturer's certificate; never exceed rated working pressure - figure is hose-specific, confirm against the certificate

Ranges are typical for this design class. Always confirm against the manufacturer documentation for your serial number.

Critical spares

  • Complete replacement hose (correct length/diameter per the fire control plan)
  • Coupling gaskets/washers
  • Hose couplings, where not integral/swaged

Safety

  • A hose that bursts under pressure during a real fire is a life-safety failure - pressure testing is not optional
  • Hoses stowed wet or found damaged should be removed from service immediately, not left for the next drill
  • Coupling thread compatibility with shore connections and the international shore connection must be verified

Class survey

Fire hoses are checked at each fire safety/annual survey against the fire control plan for correct number, length, location and condition; class expects evidence of the required pressure test and replacement of hoses that fail or exceed the manufacturer's stated service life.

Estimated lifetime: Not measured in running hours; typical calendar service life before mandatory replacement is 8-10 years, sooner if a pressure test is failed - confirm against flag state and manufacturer requirements.

Components & Design

Component data being added…

Technical Data

imo approved True

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

DNV type approval

Verified against the DNV Approval Finder — the certificate below is issued by DNV, not by us.

Certificate
MEDD00004ZE
Certificate holder
5Elem Hi-Tech Corporation (China)
Valid until
2029-12-14
Open the certificate at DNV →
Equipment Model #40815 · ✓ still in production