TNF-C72 Type Class B15 Ceiling (with B15 cover for downlight, loudspeaker)
TNF-C72 Type Class B15 Ceiling (with B15 cover for downlight, loudspeaker) by INEXA Interiors (Nantong) Co., Ltd.. DNV MED certificate MEDB000065D.
Inspector Detail
▸
Common issues
- Panel joint sealant/gasket degradation compromising fire division integrity
- Core insulation moisture ingress reducing fire/thermal performance
- Surface delamination or facing damage from mechanical impact
- Corrosion of the support grid/suspension system in humid spaces (e.g. galleys, wet units)
- Unauthorised penetrations (cables, ducts) made without maintaining the B-class rating
- Loss of certification markings making panel type/rating unverifiable after refit
Inspection checklist
- Visual check of panel surface for damage, delamination or discolouration
- Inspect joints and seams for gaps or missing sealant that would compromise B-class integrity
- Check support/suspension grid for corrosion or loose fixings
- Verify any penetrations (lights, speakers, ducting) retain approved B15 detailing per drawing
- Confirm certification/type marking is present and matches the approved fire control plan
- Check for moisture ingress or staining indicating core degradation
Service intervals
| General condition inspection | at Annual Survey / internal fire safety rounds |
| Detailed check of joints/penetrations after refit or cable/pipe work | immediately after such work, then reviewed at Annual Survey |
Critical spares
- Matching B15-rated panel/insert of the approved type, for replacing a damaged panel
- Fire-rated joint sealant/mastic of the maker-approved type
- Suspension grid and support bracket fixing hardware
Safety
- Unauthorised penetrations or removal of panels without maintaining B-class detailing compromises the fire division integrity of the accommodation
- Damaged panels reduce fire/smoke integrity of escape routes where fitted in corridors/stairways
- Panels removed for access or refit work must be reinstated with correct B15 detailing before the space is left unattended, otherwise the fire division is effectively open
Class survey
B-class divisions (here B15, i.e. 15-minute fire integrity) are verified against the ship's approved fire control plan at Annual and Renewal Survey; class checks that penetrations, joints and any modifications since build or last survey retain the certified fire rating, and that the type approval marking corresponds to the material actually fitted.
Components & Design
Component data being added…
Technical Data
🤖 Ask about this model
One free question — answered like a marine engineer. No account needed.
Suppliers & Spare Parts
Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.
📄 Request sourcing links & documentsCases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.
Start free trial →Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.
Maritime Network →DNV type approval
Verified against the DNV Approval Finder — the certificate below is issued by DNV, not by us.
- Certificate
- MEDB000065D