HKS-Gummikompensator; G 00XX / 130 / 016 / HKS-GS
HKS rubber compensator; G 00XX / 130 / 016 / HKS-GS by HKS GmbH industrial manufacturer of compensators and hoses. DNV MED certificate MEDB0000BT1.
Inspector Detail
▸
Common issues
- Rubber bellows cracking or perishing from UV, ozone, or heat exposure over time
- Delamination of the rubber-fabric plies leading to bulging or weeping under pressure
- Loss of pre-set movement capability, transferring pipe strain onto adjacent flanges
- Flange bolt loosening from vibration, causing seepage at the joint face
- Chemical attack/swelling if exposed to a media the compensator is not rated for
- Internal liner erosion in high-flow seawater applications
Inspection checklist
- Visually inspect the rubber bellows for cracking, bulging, or surface perishing around its full circumference
- Check flange bolts for correct, even torque and uniform compression of the rubber face
- Verify pipe alignment is not imposing axial/lateral movement beyond the compensator's rated range
- Check for weeping or staining at the flange faces indicating early seal failure
- Confirm the DNV MED type-approval marking/certificate is legible and matches the installed pressure/temperature rating
- Inspect any tie rods (if fitted) for corrosion and correct restraint function
Service intervals
| Visual inspection | at each planned maintenance round, typically part of routine engine room piping checks |
| Renewal | condition-based rather than a fixed running-hour interval - rubber compensators are commonly replaced on visible degradation or per the maker's stated service life, often in the order of 5-10 years depending on service temperature and media; confirm against HKS's own data sheet for this exact HKS-GS type |
Critical spares
- Complete replacement compensator of the same DN size, pressure/temperature rating, and DNV MED-approved type (HKS-GS series) - do not substitute an unapproved equivalent in a class-relevant system
- Matching flange gasket set for the compensator's connecting flanges
- Correctly rated fasteners (bolts/nuts) for the flange joint, since reused corroded fasteners are a common cause of uneven bellows compression
Safety
- A sudden bellows failure under pressure can release hot water, exhaust gas, or process fluid - depressurise and isolate the line before close inspection or removal
- Over-compression or over-extension beyond the rated movement can cause premature failure and unexpected loss of containment
- If fitted in an exhaust gas system, failure can release hot gas/soot into the machinery space - treat as a fire and burn hazard
Class survey
As a DNV MED type-approved component (certificate MEDB0000BT1), this item is subject to approval-status and installation-conformity checks at survey rather than an internal inspection of the rubber itself. Class verifies that the fitted compensator's certificate matches the piping system's design pressure, temperature, and medium, and that it has not been substituted with an unapproved equivalent.
Components & Design
Component data being added…
Technical Data
🤖 Ask about this model
One free question — answered like a marine engineer. No account needed.
Suppliers & Spare Parts
Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.
📄 Request sourcing links & documentsCases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.
Start free trial →Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.
Maritime Network →DNV type approval
Verified against the DNV Approval Finder — the certificate below is issued by DNV, not by us.
- Certificate
- MEDB0000BT1