Auxiliary Engine (Generator Set) · Auxiliary Engines
The MAN 7L16/24 is an inline 4‑stroke turbocharged diesel auxiliary engine delivering up to ~770 kW at 1200 rpm, designed for shipboard power generation and compliance with IMO Tier II emissions limits.
Do you have the manufacturer datasheet for this model? Send it with the enquiry form — we check it and name the source.
What our service work and the manufacturer documentation say about keeping this model running.
Operate with correct fuel heating and separator performance. Scheduled maintenance includes fuel valve exchange, exhaust valve inspection and lube oil analysis.
| Lube Oil Analysis | Monthly or every 250-500 running hours |
|---|---|
| Fuel Filter Element Replacement | 500-1000 running hours |
| Air Filter Cleaning/Replacement | 1000-2000 running hours |
| Fuel Valve (Injector) Exchange/Overhaul | 3000-4000 running hours (HFO), 6000-8000 running hours (MDO) |
| Exhaust Valve Inspection/Overhaul | 3000-4000 running hours (HFO), 6000-8000 running hours (MDO) |
| Turbocharger Inspection/Cleaning | 3000-6000 running hours |
| Cylinder Head Overhaul (Top End) | 12,000-18,000 running hours |
| Major Overhaul (Bottom End Bearings, Pistons, Liners) | 24,000-36,000 running hours |
| Cylinder Liner Wear (Max Ovality/Taper) | 0.6 - 0.8 mm |
|---|---|
| Piston Ring Groove Clearance (Max Increase) | 0.15 - 0.20 mm |
| Crankshaft Deflection (Max Deviation) | 0.05 mm (between adjacent webs) |
| Main/Big End Bearing Clearance (Max) | 0.25 - 0.30 mm |
| Exhaust Valve Seat Recession (Max from New) | 1.5 mm |
| Fuel Nozzle Opening Pressure | 280 - 300 bar (tolerance +/- 5 bar) |
Ranges are typical for this design class. Always confirm against the manufacturer documentation for your serial number.
Class surveyors typically focus on the overall condition and operational safety. Key checks include: verification of engine safety devices (overspeed trip, low lube oil pressure, high cooling water temperature, low starting air pressure); integrity of fuel oil systems (leakage, fire fighting arrangements, double-walled piping); generator insulation resistance and earth fault detection; condition of foundation bolts; exhaust gas system integrity; and general visual inspection for leaks, corrosion, and abnormal wear. Documentation review of maintenance records, running hours, lube oil analysis reports, and previous survey recommendations is crucial. Crankshaft deflection readings may be requested during major surveys or if abnormal vibrations are reported. A load test of the genset is often required to confirm stable operation and output.
Estimated lifetime: 60,000 - 80,000 hours before major replacement or extensive rebuild
Carry fuel valves, exhaust valves, o-rings, head gasket sets, filters and fuel pump spares.
Free of charge — send us your request for MAN Energy Solutions equipment. Our team checks it and replies by e-mail.
Other models of the same equipment type, MAN Energy Solutions first.
Tell us what you need for this MAN Energy Solutions 7L16/24 GenSet — a part, a service call, a second opinion. Are you MAN Energy Solutions? Claim this brand page.
Service engineer? Write the day report for this 7L16/24 GenSet in OceanSphere Work — photos, hours and parts, as a PDF for the owner. Try it free for 14 days →
Yes. Specifications, documents and service notes for this model are readable without an account. An account adds saved searches and requests, nothing is taken away.
Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.
Send us the nameplate or the correct value. We check it against the manufacturer datasheet or class-society record and update the page.