Measuring ranges DD0 to 100% LEL
Measuring ranges LC0 to 10% LEL
Signal output analogue4 to 20 mA
MaintenanceConstant 3.4 mA or 4 mA
Fault< 1.2 mA
Power supply10 to 30 V DC, 3-wire
Power consumption (max.) DrägerSensor® Ex ... DD, w/o relay, non-remote105 mA at 24 V
Power consumption (max.) DrägerSensor® Ex ... DD, w/ relay, remote145 mA at 24 V
Power consumption (max.) DrägerSensor® Ex LC, w/o relay, non-remote130 mA at 24 V
Power consumption (max.) DrägerSensor® Ex LC, w/ relay, remote165 mA at 24 V
Temperature-40 to 80°C (-40 to 176°F) without relay
Pressure20.7 to 38.4 inch Hg / 700 to 1,300 mbar
Humidity0 to 100% r. h., non-condensing
Dimensions w/ docking station11.0" x 7.1" x 7.5" / 280 x 180 x 190 mm
Weight, approx. w/o docking station Aluminium4.9 lbs / 2.2 kg
Weight, approx. w/o docking station SS316 L8.8 lbs / 4.0 kg
Need this part?

Request a quote for this model.

Free of charge — send us your request for Hanla IMS equipment. Our team checks it and replies by e-mail.

For marine equipment hardly any maker or authorised dealer will name a price while the vessel is unknown. With the vessel details, availability and price can be settled faster; without them we may have to ask first, which costs a few days. If you are not allowed to name the vessel, a photo of the rating plate is enough — attach it below or send it as a reply to our confirmation e-mail.

Your contact details are not published. No account required.
Related models

Also in Fixed Gas Detection System.

Other models of the same equipment type, Hanla IMS first.

By manufacturer RKI InstrumentsDrägerRiken KeikiMSA SafetyCrowconAFRISOHoneywell AnalyticsDet-TronicsIndustrial ScientificGfG InstrumentationDräger Safety AG & Co. KGaAHanla IMSAutronicaEndress+HauserVaisalaAll manufacturersSpare parts by equipmentNew here? Create a free account Can't read the plate? Try the nameplate scanner All Hanla IMS models More like 8200 CAT
More than the data sheet shows

We answer by e-mail, never with an automatic reply.

Tell us what you need for this Hanla IMS 8200 CAT — a part, a service call, a second opinion. Are you Hanla IMS? Claim this brand page.

Service engineer? Write the day report for this 8200 CAT in OceanSphere Work — photos, hours and parts, as a PDF for the owner. Try it free for 14 days →

Frequently asked

Questions that come up with this equipment.

Is this model's data free?

Yes. Specifications, documents and service notes for this model are readable without an account. An account adds saved searches and requests, nothing is taken away.

Can you find a part for this exact model?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.

The specifications look wrong — what now?

Send us the nameplate or the correct value. We check it against the manufacturer datasheet or class-society record and update the page.