Terminal voltage U at the device13 to 35 V
Maximum load R, depending on the supply voltage U0 at the supply unit500
Antenna size150 mm (6 in) / 200 mm (8 in) / 250 mm (10 in)
Beam angle α23°
Distance (D)3 m (9.8 ft)
Beamwidth diameter W1.22 m (4 ft)
Antenna length540 mm (21.3 in)
Nozzle height H< 250 mm (9.84 in)
HousingGT18 (316 L)
Ta-196 (-321)
Tp80 (176)
Power Supply; Output (Pos. 2-40 °C (°F)
A-40 °C (°F)
B-40 °C (°F)
C-40 °C (°F)
E, G-40 °C (°F)
BC: Horn80mm/3"
BD: Horn100mm/4"
BE: Horn150mm/6"
BF: Horn200mm/8"
BG: Horn250mm/10"
L68 mm (2.68 in)
D75 mm
L1341 mm (13.4 in)
B22 mm (0.87 in)
Weight of antenna and process connectionmax. 9 kg (19.9 lb)
Max. pressure100 bar (1 450 psi)
Minimum value400 mm (16 in)
Minimum spanF ≥ 400 mm (16 in)
Maximum value for Empty calibrationE ≤ 20 m (66 ft)
Power supply; output9 to 32 V 3)
Power consumption< 0.9 W
Current consumption HART3.6 to 22 mA
Breakdown signal HARTadjustable: 3.59 to 22.5 mA
PROFIBUS PA Nominal current14 mA
Beam diameter W1.22 m (4 ft)
Antenna150mm/6"
Temperature specifications: °C (°F)-40 80 80 80 150 60 150 -40
Process temperature range–40 to +150 °C (–40 to +302 °F)
Nominal diameter80A
Pressure rating10 K
L2250 mm
Max. pressure100 bar (1 450 psi)
Length L1:100 mm (4 in), 200 mm (8 in), 300 mm (12 in), 400 mm (16 in)
Radio standardEN302372-1/2
FCC / Industry CanadaPart 15 of the FCC rules.
Terminal voltage13 to 28 V
Flange size10K 80A
Recommended torque [Nm]25 minimum
Ambient temperature range–40 to +80 °C (–40 to +176 °F); –50 °C (–58 °F) with manufacturer declaration on
Local display–20 to +70 °C (–4 to +158 °F), the readability of the display may be impaired at
Remote display FHX50–40 to 80 °C (–40 to 176 °F)
Remote display FHX50 (option)–50 to 80 °C (–58 to 176 °F)
Power Supply; Output (Pos. 2 of the product structure)-196 81 81 81 400 31 400 -40 (-321) (178) (178)
Power Supply; Output (Pos. 2 of the product structure)-196 °C
Process temperature-40 to +150 °C
Process pressure-1 to 40 bar
SealGraphite, -196...400°C/-321...752°F (HT)
Pressure rating 1)150 lbs
WeightHousing GT18 - stainless steel approx. 4.5 kg (9.9 lb)
Antenna type/sizeHorn 150 mm (6 in)
Minimum starting voltage17.5 V
Starting time80 s
Minimum operating voltage17.5 V
Multidrop current4.0 mA
Time for connection setup30 s
Terminal voltage U at device10.4 to 35 V 3) 4) 5)
Antenna type and size150 mm (6 in)
Minimum alarm3.6 mA
Maximum alarm (= factory setting)22 mA
Failsafe mode with user-selectable value3.59 to 22.5 mA
Manufacturer ID17 (0x11)
Device type ID0x1128
HART specification7.0
HART loadmin. 250 Ω
Supply voltage10.4 to 30 V 3)
Maximum load500 Ω
Nominal current3.6 to 22 mA
Ui17.5 V
Ii550 mA
Pi5.5 W
Li10 μH
Measuring distance (D)6 m (20 ft)
Process temperature, Process pressure–40 to +150 °C (–40 to +302 °F) °C ( °F)
Admissible process temperature–40 to +150 °C
Admissible process pressure–1 to 64 bar
Dimension 155 mm155 mm (6.1 in)
Dimension BC80 mm
Dimension BD100 mm
Dimension BE150 mm
Dimension BF200 mm
Dimension BG250 mm
Dimension L68 mm
Dimension ød75 mm
Dimension øD95 mm
Tightening torque25 to 35 Nm
Length of antenna540 mm (21.3 in)
Antenna inactive length< 100 mm (3.94 in)
Εr2.3 2.1 2.3 3.1
Temperature range–40 to +80 °C (–40 to +176 °F); –50 °C (–58 °F) with manufacturer declaration on
Abstrahlwinkel α23 °
Distanz (D)3 m (9,8 ft)
Kegeldurchmesser W1,22 m (4 ft)
Antennengröße200 mm (8 in)
GerätFMR54
Hornantenne50 mm (1,97 in) > 0,5 m (1,6 ft) 150…300 mm (5,91…11,8 in) > 1,5 m (4,9 ft)
Planarantenne1 m (3,28 ft)
FlanschgrößeDN50/PN16
empfohlenes Anzugsdrehmoment [Nm]45 65
Druckstufe10 K
Nominal size80A
Druck-stufe150 lbs
Antennentyp/-größeHorn 150 mm (6 in)
Signalkodierung HARTFSK ±0,5 mA über dem Stromsignal
Datenübertragungsrate HART1 200 Bit/s
Datenübertragungsrate Bluetooth®> 10 m (33 ft)
Datenübertragungsrate PROFIBUS PA31,25 kBit/s, Voltage Mode
Datenübertragungsrate FOUNDATION Fieldbus31,25 kBit/s, Voltage Mode
Minimale Anlaufspannung17,5 V
Anlaufzeit80 s
Minimale Betriebsspannung17,5 V
Multidrop-strom4,0 mA
Zeit für Verbindungsaufbau30 s
Klemmenspannung U am Gerät10,4 … 35 V
Maximale Bürde R, abhängig von der Versorgungsspannung U0 des Speisegeräts500
Maximale Bürde Rmax500 Ω
Leistungsaufnahme< 0,9 W
Nennstrom HART3,6 … 22 mA
Ausfallsignal (NAMUR NE43)einstellbar: 3,59 … 22,5 mA
Nennstrom PROFIBUS PA14 mA
Antennehorn 150 mm (6 in), α23 °
Jis10K 50A
Anzugsdrehmoment40 … 60 Nm
Antennenlänge540 mm (21,3 in)
Antenne200mm/8"
Temperaturangaben: °C (°F)-40 81 81 81 200 57 200 -40
K, L-196 ... 77 ... 77 ... 77 ... 400 ... 40 ... 400 ... -40 ... -40 ... -40 ... -19
Maximale Bürde R, abhängig von der Versorgungsspannung500
Hersteller-id17 (0x11)
Ident number0x1559
Profil-version3.02
77(3.03)77 mm
Druck-stufe 1)150 lbs
Abmessung b27 mm (1,06 in)
Power Supply; Output2-wire; 4-20mA HART, 4-20mA
V6.7 V
Nozzle diameter D191 mm (7.52 in) - 268 mm (10.6 in)
Tp max24 MWP
D146 mm (5.75 in)
H< 205 mm (8.07 in)
Klemmenspannung9 … 30 V
empfohlenes Anzugsdrehmoment [Nm] minimal40 Nm
empfohlenes Anzugsdrehmoment [Nm] maximal60 Nm
Versorgungsspannung2-Draht, 4-20mA HART, passiv
Maximale Bürde R500 W
Abgleich VollF vom minimalen Füllstand (0%) zum maximalen Füllstand (100%)
Stutzenhöhe Hmax268 mm (10,6 in)
Rohrdurchmesser0 ... 9999 mm (0 ... 390 inch)
Maximal erlaubtes Drehmoment60 Nm (44 lbf ft)
Klemmenspannung U12…30 V
Klemmenbelegung2-Draht: 4 … 20 mA HART
Maximale Bürde500
Anlaufstrom4 mA
Fehlerstrom FDE (Fault Disconnection Electronic)0 mA