OceanSphereENGINES

FMR54

Radar Level Gauge · Cargo Level & Temperature Gauging

Class-certified type (DNV register) · technical data sheet not yet verified​⁠​‌‌​⁠‍⁠‍‌​‌‌​⁠‌‌⁠‌
View photo ↗
Specifications

Technical data.reference — unverified

Do you have the manufacturer datasheet for this model? Send it with the enquiry form — we check it and name the source.

Terminal voltage U at the device13 to 35 V
Maximum load R, depending on the supply voltage U0 at the supply unit500
Antenna size150 mm (6 in) / 200 mm (8 in) / 250 mm (10 in)
Beam angle α23°
Distance (D)3 m (9.8 ft)
Beamwidth diameter W1.22 m (4 ft)
Antenna length540 mm (21.3 in)
Nozzle height H< 250 mm (9.84 in)
HousingGT18 (316 L)
Ta-196 (-321)
Tp80 (176)
Power Supply; Output (Pos. 2-40 °C (°F)
A-40 °C (°F)
B-40 °C (°F)
C-40 °C (°F)
E, G-40 °C (°F)
BC: Horn80mm/3"
BD: Horn100mm/4"
BE: Horn150mm/6"
BF: Horn200mm/8"
BG: Horn250mm/10"
L68 mm (2.68 in)
D75 mm
L1341 mm (13.4 in)
B22 mm (0.87 in)
Weight of antenna and process connectionmax. 9 kg (19.9 lb)
Max. pressure100 bar (1 450 psi)
Minimum value400 mm (16 in)
Minimum spanF ≥ 400 mm (16 in)
Maximum value for Empty calibrationE ≤ 20 m (66 ft)
Power supply; output9 to 32 V 3)
Power consumption< 0.9 W
Current consumption HART3.6 to 22 mA
Breakdown signal HARTadjustable: 3.59 to 22.5 mA
PROFIBUS PA Nominal current14 mA
Beam diameter W1.22 m (4 ft)
Antenna150mm/6"
Temperature specifications: °C (°F)-40 80 80 80 150 60 150 -40
Process temperature range–40 to +150 °C (–40 to +302 °F)
Nominal diameter80A
Pressure rating10 K
L2250 mm
Max. pressure100 bar (1 450 psi)
Length L1:100 mm (4 in), 200 mm (8 in), 300 mm (12 in), 400 mm (16 in)
Radio standardEN302372-1/2
FCC / Industry CanadaPart 15 of the FCC rules.
Terminal voltage13 to 28 V
Flange size10K 80A
Recommended torque [Nm]25 minimum
Ambient temperature range–40 to +80 °C (–40 to +176 °F); –50 °C (–58 °F) with manufacturer declaration on
Local display–20 to +70 °C (–4 to +158 °F), the readability of the display may be impaired at
Remote display FHX50–40 to 80 °C (–40 to 176 °F)
Remote display FHX50 (option)–50 to 80 °C (–58 to 176 °F)
Power Supply; Output (Pos. 2 of the product structure)-196 81 81 81 400 31 400 -40 (-321) (178) (178)
Power Supply; Output (Pos. 2 of the product structure)-196 °C
Process temperature-40 to +150 °C
Process pressure-1 to 40 bar
SealGraphite, -196...400°C/-321...752°F (HT)
Pressure rating 1)150 lbs
WeightHousing GT18 - stainless steel approx. 4.5 kg (9.9 lb)
Antenna type/sizeHorn 150 mm (6 in)
Minimum starting voltage17.5 V
Starting time80 s
Minimum operating voltage17.5 V
Multidrop current4.0 mA
Time for connection setup30 s
Terminal voltage U at device10.4 to 35 V 3) 4) 5)
Antenna type and size150 mm (6 in)
Minimum alarm3.6 mA
Maximum alarm (= factory setting)22 mA
Failsafe mode with user-selectable value3.59 to 22.5 mA
Manufacturer ID17 (0x11)
Device type ID0x1128
HART specification7.0
HART loadmin. 250 Ω
Supply voltage10.4 to 30 V 3)
Maximum load500 Ω
Nominal current3.6 to 22 mA
Ui17.5 V
Ii550 mA
Pi5.5 W
Li10 μH
Measuring distance (D)6 m (20 ft)
Process temperature, Process pressure–40 to +150 °C (–40 to +302 °F) °C ( °F)
Admissible process temperature–40 to +150 °C
Admissible process pressure–1 to 64 bar
Dimension 155 mm155 mm (6.1 in)
Dimension BC80 mm
Dimension BD100 mm
Dimension BE150 mm
Dimension BF200 mm
Dimension BG250 mm
Dimension L68 mm
Dimension ød75 mm
Dimension øD95 mm
Tightening torque25 to 35 Nm
Length of antenna540 mm (21.3 in)
Antenna inactive length< 100 mm (3.94 in)
Εr2.3 2.1 2.3 3.1
Temperature range–40 to +80 °C (–40 to +176 °F); –50 °C (–58 °F) with manufacturer declaration on
Abstrahlwinkel α23 °
Distanz (D)3 m (9,8 ft)
Kegeldurchmesser W1,22 m (4 ft)
Antennengröße200 mm (8 in)
GerätFMR54
Hornantenne50 mm (1,97 in) > 0,5 m (1,6 ft) 150…300 mm (5,91…11,8 in) > 1,5 m (4,9 ft)
Planarantenne1 m (3,28 ft)
FlanschgrößeDN50/PN16
empfohlenes Anzugsdrehmoment [Nm]45 65
Druckstufe10 K
Nominal size80A
Druck-stufe150 lbs
Antennentyp/-größeHorn 150 mm (6 in)
Signalkodierung HARTFSK ±0,5 mA über dem Stromsignal
Datenübertragungsrate HART1 200 Bit/s
Datenübertragungsrate Bluetooth®> 10 m (33 ft)
Datenübertragungsrate PROFIBUS PA31,25 kBit/s, Voltage Mode
Datenübertragungsrate FOUNDATION Fieldbus31,25 kBit/s, Voltage Mode
Minimale Anlaufspannung17,5 V
Anlaufzeit80 s
Minimale Betriebsspannung17,5 V
Multidrop-strom4,0 mA
Zeit für Verbindungsaufbau30 s
Klemmenspannung U am Gerät10,4 … 35 V
Maximale Bürde R, abhängig von der Versorgungsspannung U0 des Speisegeräts500
Maximale Bürde Rmax500 Ω
Leistungsaufnahme< 0,9 W
Nennstrom HART3,6 … 22 mA
Ausfallsignal (NAMUR NE43)einstellbar: 3,59 … 22,5 mA
Nennstrom PROFIBUS PA14 mA
Antennehorn 150 mm (6 in), α23 °
Jis10K 50A
Anzugsdrehmoment40 … 60 Nm
Antennenlänge540 mm (21,3 in)
Antenne200mm/8"
Temperaturangaben: °C (°F)-40 81 81 81 200 57 200 -40
K, L-196 ... 77 ... 77 ... 77 ... 400 ... 40 ... 400 ... -40 ... -40 ... -40 ... -19
Maximale Bürde R, abhängig von der Versorgungsspannung500
Hersteller-id17 (0x11)
Ident number0x1559
Profil-version3.02
77(3.03)77 mm
Druck-stufe 1)150 lbs
Abmessung b27 mm (1,06 in)
Power Supply; Output2-wire; 4-20mA HART, 4-20mA
V6.7 V
Nozzle diameter D191 mm (7.52 in) - 268 mm (10.6 in)
Tp max24 MWP
D146 mm (5.75 in)
H< 205 mm (8.07 in)
Klemmenspannung9 … 30 V
empfohlenes Anzugsdrehmoment [Nm] minimal40 Nm
empfohlenes Anzugsdrehmoment [Nm] maximal60 Nm
Versorgungsspannung2-Draht, 4-20mA HART, passiv
Maximale Bürde R500 W
Abgleich VollF vom minimalen Füllstand (0%) zum maximalen Füllstand (100%)
Stutzenhöhe Hmax268 mm (10,6 in)
Rohrdurchmesser0 ... 9999 mm (0 ... 390 inch)
Maximal erlaubtes Drehmoment60 Nm (44 lbf ft)
Klemmenspannung U12…30 V
Klemmenbelegung2-Draht: 4 … 20 mA HART
Maximale Bürde500
Anlaufstrom4 mA
Fehlerstrom FDE (Fault Disconnection Electronic)0 mA
Manufacturer documentation

Images from manufacturer documentation.

Photos, drawings and page previews from this model’s datasheet or catalog.

The Micropilot FMR54 is a level measurement device with a horn antenna designed for accurate level detection in various industrial applications.

Applications

  • boiling surfaces
  • bubbling
  • foaming
  • heavy steam
  • condensate
  • absorbing gases

Features

  • measuring range up to 20 meters
  • various antenna sizes
  • accurate level detection

Options

  • Advanced dynamics option for FMR50, FMR51, and FMR52

Standards

  • ASME B16.5 / EN1092-1 / JIS B2220
Source: Endress+Hauser FMR54 datasheet, p. 66
Endress+Hauser FMR54 – Photo (41bd56ca85a8_S1-10 S. 1)
Photo · 41bd56ca85a8_S1-10 · S. 1
Endress+Hauser FMR54 – Photo (f41a53322277_S1-99 S. 1)
Photo · f41a53322277_S1-99 · S. 1
Endress+Hauser FMR54 – Photo (b7a85db93d0e_S1-110 S. 1)
Photo · b7a85db93d0e_S1-110 · S. 1
Endress+Hauser FMR54 – Drawing (41bd56ca85a8_S1-10 S. 1)
Drawing · 41bd56ca85a8_S1-10 · S. 1
Endress+Hauser FMR54 – Drawing (41bd56ca85a8_S1-10 S. 2)
Drawing · 41bd56ca85a8_S1-10 · S. 2
Endress+Hauser FMR54 – Drawing (41bd56ca85a8_S1-10 S. 3)
Drawing · 41bd56ca85a8_S1-10 · S. 3
Endress+Hauser FMR54 – Page preview (41bd56ca85a8_S1-10 S. 4)
Page preview · 41bd56ca85a8_S1-10 · S. 4
Endress+Hauser FMR54 – Page preview (41bd56ca85a8_S1-10 S. 5)
Page preview · 41bd56ca85a8_S1-10 · S. 5
Source: Endress+Hauser FMR54 datasheet, p. 36
Need this part?

Request a quote for this model.

Free of charge — send us your request for Endress+Hauser equipment. Our team checks it and replies by e-mail.

For marine equipment hardly any maker or authorised dealer will name a price while the vessel is unknown. With the vessel details, availability and price can be settled faster; without them we may have to ask first, which costs a few days. If you are not allowed to name the vessel, a photo of the rating plate is enough — attach it below or send it as a reply to our confirmation e-mail.

Your contact details are not published. No account required.
Related models

Also in Radar Level Gauge.

Other models of the same equipment type, Endress+Hauser first.

By manufacturer Endress+HauserKrohneEmerson RosemountVEGATokyo KeikiBarksdaleDanfossPanasiaSiemensNORIS AutomationEmersonHanla IMSHoneywellIfm ElectronicJUMOAll manufacturersSpare parts by equipmentNew here? Create a free account Can't read the plate? Try the nameplate scanner All Endress+Hauser models More like FMR54
More than the data sheet shows

We answer by e-mail, never with an automatic reply.

Tell us what you need for this Endress+Hauser FMR54 — a part, a service call, a second opinion. Are you Endress+Hauser? Claim this brand page.

Service engineer? Write the day report for this FMR54 in OceanSphere Work — photos, hours and parts, as a PDF for the owner. Try it free for 14 days →

Frequently asked

Questions that come up with this equipment.

Is this model's data free?

Yes. Specifications, documents and service notes for this model are readable without an account. An account adds saved searches and requests, nothing is taken away.

Can you find a part for this exact model?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.

The specifications look wrong — what now?

Send us the nameplate or the correct value. We check it against the manufacturer datasheet or class-society record and update the page.