Terminal voltage U at the device10.4 to 30 V
Maximum load R, depending on the supply voltage U0 at the supply unit500
Beam angle α23°
Measuring distance (D)3 m (9.8 ft)
Beamwidth diameter W1.22 m (4 ft)
DeviceFMR53
A50 mm (1,97 in) > 0,5 m (1,6 ft)
C150…300 mm (5,91…11,8 in)
Mounting cladded flangesFor cladded flanges of FMR53, observe the following:
Flange sizeDN50/PN16
B> 0,5 m (1,6 ft)
Antenna length390 mm (15.4 in)
Nozzle height H< 100 mm (3.94 in)
HousingGT18 (316 L)
Process temperature-40 to +150 °C
Process pressure-1 to 40 bar
Antenna length L1390 mm mm (15.4 in)
Inactive length L2100 mm mm (3.94 in)
Weight of antenna and process connectionmax. 3.0 kg (6.6 lb) + weight of flange 1)
Power supply; output9 to 32 V 3)
Power consumption< 0.9 W
Current consumption HARTNominal current 3.6 to 22 mA, the start-up current for multidrop mo
Breakdown signal HARTadjustable: 3.59 to 22.5 mA
PROFIBUS PA Nominal current14 mA
Distance (D)3 m (9.8 ft)
Beam diameter W1.22 m (4 ft)
Antenna150mm/6"
Process pressure rangepgauge = –1 to 3 bar (–14.5 to 43.5 psi)
Nominal diameter50A
Pressure rating10 K
Ød155 mm (6,1 in)
L1390 mm
L2100 mm
Weight of antenna/process connectionMax. 3.0 kg (6.6 lb) + flange weight 1)
Radio standardEN302372-1/2
FCC / Industry CanadaPart 15 of the FCC rules.
Terminal voltage13 to 35 V
Temperature+24 °C (+75 °F) ±5 °C (±9 °F)
Pressure960 mbar abs. (14 psia) ±100 mbar (±1.45 psi)
Humidity60 % ±15 %
Reflectormetal plate with a minimum diameter of 1 m (40 in)
Maximum measured error± 6 mm (0.24 in) ± 0.02 %
Offset/zero± 4 mm (0.2 in) ± 0.03 %
Recommended torque [Nm]40 minimum
Ambient temperature range–40 to +80 °C (–40 to +176 °F); –50 °C (–58 °F) with manufacturer declaration on
Local display–20 to +70 °C (–4 to +158 °F), the readability of the display may be impaired at
Remote display FHX50–40 to 80 °C (–40 to 176 °F)
Remote display FHX50 (option)–50 to 80 °C (–58 to 176 °F)
CB: Rod540 mm (21.3 in) mm (in)
Pressure rating 1)300 lbs
WeightHousing GT18 - stainless steel approx. 4.5 kg (9.9 lb)
Allowable pressure≤ 200 bar (2 900 psi)
Antenna type/sizeRod 390 mm (15 in)
Measuring range [m (ft)]10 (33)
Minimum starting voltage17.5 V
Starting time80 s
Minimum operating voltage17.5 V
Multidrop current4.0 mA
Time for connection setup30 s
Terminal voltage U at device10.4 to 35 V 3) 4) 5)
Antenna type and size390 mm (15 in)
Minimum alarm3.6 mA
Maximum alarm (= factory setting)22 mA
Failsafe mode with user-selectable value3.59 to 22.5 mA
Manufacturer ID17 (0x11)
Device type ID0x1128
HART specification7.0
HART loadmin. 250 Ω
Supply voltage10.4 to 35 V 3)
Maximum load500 Ω
Nominal current3.6 to 22 mA
Ui17.5 V
Ii550 mA
Pi5.5 W
Li10 μH
Nozzle height an diameter for the rod antenna11
Process temperature, Process pressure–40 to +80 °C (–40 to +176 °F) °C ( °F)
Dimension 155 mm155 mm (6.1 in)
Pressure equipment with allowable pressure≤ 200 bar (2 900 psi)
Tightening torque40 to 60 Nm
Antenna inactive length< 100 mm (3.94 in)
Εr2.3 2.1 2.3 3.1
Temperature range–40 to +80 °C (–40 to +176 °F); –50 °C (–58 °F) with manufacturer declaration on
Process temperature range [°C]–40 to +80 °C
Ø33 (1.3)ø33 (1.3)
Inactive length100 mm (3.94 in)
Length of antenna540 mm (21.3 in)
Abstrahlwinkel α23 °
Distanz (D)3 m (9,8 ft)
Kegeldurchmesser W1,22 m (4 ft)
Antennengröße150 mm (6 in)
GerätFMR53
Hornantenne50 mm (1,97 in) > 0,5 m (1,6 ft) 150…300 mm (5,91…11,8 in) > 1,5 m (4,9 ft)
Planarantenne1 m (3,28 ft)
FlanschgrößeDN50/PN16
empfohlenes Anzugsdrehmoment [Nm]45 65
Prozesstemperaturbereich–40 … +80 °C (–40 … +176 °F)
Druckstufe10 K
Nominal size50A 80A 100A 150A
Abmessung b155 mm (6,1 in)
Druck-stufe150 lbs
Antennentyp/-größeStab 390 mm (15 in)
Signalkodierung HARTFSK ±0,5 mA über dem Stromsignal
Datenübertragungsrate HART1 200 Bit/s
Datenübertragungsrate Bluetooth®> 10 m (33 ft)
Datenübertragungsrate PROFIBUS PA31,25 kBit/s, Voltage Mode
Datenübertragungsrate FOUNDATION Fieldbus31,25 kBit/s, Voltage Mode
Minimale Anlaufspannung17,5 V
Anlaufzeit80 s
Minimale Betriebsspannung17,5 V
Multidrop-strom4,0 mA
Zeit für Verbindungsaufbau30 s
Klemmenspannung U am Gerät10,4 … 35 V
Maximale Bürde R, abhängig von der Versorgungsspannung U0 des Speisegeräts500
Maximale Bürde Rmax500 Ω
Leistungsaufnahme< 0,9 W
Nennstrom HART3,6 … 22 mA
Ausfallsignal (NAMUR NE43)einstellbar: 3,59 … 22,5 mA
Nennstrom PROFIBUS PA14 mA
Antennehorn 150 mm (6 in), α23 °
Jis10K 50A
Anzugsdrehmoment40 … 60 Nm
Antenne150mm/6"
Prozessdruckbereichprel = –1 … 3 bar (–14,5 … 43,5 psi)
Maximale Bürde R, abhängig von der Versorgungsspannung500
Gewicht Antenne/Prozessanschlussmax. 3,0 kg (6,6 lb) + Flanschgewicht 1)
Hersteller-id17 (0x11)
Ident number0x1559
Profil-version3.02
Abmessung D155 mm (6,1 in)
Druck-stufe 1)150 lbs
Power Supply; Output2-wire; 4-20mA HART, 4-20mA
H> 1,5 m (4,9 ft)
V6.7 V
Antenna size150 mm (6 in)
Antenna diameter50 mm (1.97 in)
Mounting distance> 0.5 m (1.6 ft)
Tp max24 MWP
Hilfsenergie;ausgangXA00681F
Klemmenspannung9…32 V 3)
empfohlenes Anzugsdrehmoment [Nm] minimal40 Nm
empfohlenes Anzugsdrehmoment [Nm] maximal60 Nm
Übergängemax. 1 mm (0,04 in)
Versorgungsspannung2-Draht, 4-20mA HART, passiv
Maximale Bürde R500 W
Abgleich VollF vom minimalen Füllstand (0%) zum maximalen Füllstand (100%)
Diameter50 mm (1,97 in)
Stutzenhöhe Hmax185 mm (7,28 in)
Rohrdurchmesser0 ... 9999 mm (0 ... 390 inch)
Antennenlänge540 mm (21,3 in)
Maximal erlaubtes Drehmoment35 Nm (26 lbf ft)
Klemmenbelegung2-Draht: 4 … 20 mA HART
Maximale Bürde500 W
Anlaufstrom4 mA
Fehlerstrom FDE (Fault Disconnection Electronic)0 mA
Manufacturer documentation

Images from manufacturer documentation.

Photos, drawings and page previews from this model’s datasheet or catalog.

The Micropilot FMR53 and FMR54 are radar level measurement devices designed to optimize measurement accuracy by reducing interference echoes.

Applications

  • liquid level measurement

Features

  • adjustable antenna size
  • electronic suppression of interference echoes
  • stilling well application

Options

  • antenna alignment
  • metallic screens at a slope

Standards

  • EN 1092-1: 2001 Tab. 18
  • ASME B 16.5a - 1998 Tab. 2-2.2 F316
  • ASME B 16.5a - 1998 Tab. 2.3.8 N10276
  • JIS B 2220
Source: Endress+Hauser FMR53 datasheet, p. 58
Endress+Hauser FMR53 – Photo (7093eafd1f4c_S1-10 S. 1)
Photo · 7093eafd1f4c_S1-10 · S. 1
Endress+Hauser FMR53 – Photo (1eab879fdd94_S1-99 S. 1)
Photo · 1eab879fdd94_S1-99 · S. 1
Endress+Hauser FMR53 – Photo (00e8ab53a670_S1-110 S. 1)
Photo · 00e8ab53a670_S1-110 · S. 1
Endress+Hauser FMR53 – Drawing (7093eafd1f4c_S1-10 S. 1)
Drawing · 7093eafd1f4c_S1-10 · S. 1
Endress+Hauser FMR53 – Drawing (7093eafd1f4c_S1-10 S. 2)
Drawing · 7093eafd1f4c_S1-10 · S. 2
Endress+Hauser FMR53 – Drawing (7093eafd1f4c_S1-10 S. 3)
Drawing · 7093eafd1f4c_S1-10 · S. 3
Endress+Hauser FMR53 – Page preview (7093eafd1f4c_S1-10 S. 4)
Page preview · 7093eafd1f4c_S1-10 · S. 4
Endress+Hauser FMR53 – Page preview (7093eafd1f4c_S1-10 S. 5)
Page preview · 7093eafd1f4c_S1-10 · S. 5
Source: Endress+Hauser FMR53 datasheet, p. 35
Need this part?

Request a quote for this model.

Free of charge — send us your request for Endress+Hauser equipment. Our team checks it and replies by e-mail.

For marine equipment hardly any maker or authorised dealer will name a price while the vessel is unknown. With the vessel details, availability and price can be settled faster; without them we may have to ask first, which costs a few days. If you are not allowed to name the vessel, a photo of the rating plate is enough — attach it below or send it as a reply to our confirmation e-mail.

Your contact details are not published. No account required.
Related models

Also in Radar Level Gauge.

Other models of the same equipment type, Endress+Hauser first.

By manufacturer Endress+HauserKrohneEmerson RosemountVEGATokyo KeikiBarksdaleDanfossPanasiaSiemensNORIS AutomationEmersonHanla IMSHoneywellIfm ElectronicJUMOAll manufacturersSpare parts by equipmentNew here? Create a free account Can't read the plate? Try the nameplate scanner All Endress+Hauser models More like FMR53
More than the data sheet shows

We answer by e-mail, never with an automatic reply.

Tell us what you need for this Endress+Hauser FMR53 — a part, a service call, a second opinion. Are you Endress+Hauser? Claim this brand page.

Service engineer? Write the day report for this FMR53 in OceanSphere Work — photos, hours and parts, as a PDF for the owner. Try it free for 14 days →

Frequently asked

Questions that come up with this equipment.

Is this model's data free?

Yes. Specifications, documents and service notes for this model are readable without an account. An account adds saved searches and requests, nothing is taken away.

Can you find a part for this exact model?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.

The specifications look wrong — what now?

Send us the nameplate or the correct value. We check it against the manufacturer datasheet or class-society record and update the page.