Reference operating conditionsAmbient temperature: +23 °C (+73 °F)
Minimum distance between the tuning fork and the tank wall or pipe wall:10 mm (0.39 in)
Maximum measured errorAt reference operating conditions:
Plastic coating:–0.2 to –1.2 mm (–0.008 to –0.05 in)
Enamel coating:0 to 0.9 mm (0 to 0.04 in)
ResolutionCurrent output: < 1 µA
Terminal assignmentOUT 0.5A
Supply voltage12 to 30 VDC on a direct current power unit
Overvoltage protectionThe device satisfies the IEC/DIN EN 61326-1 product standard (Table 2 Industrial
Weight, housing including electronics and onsite display0.2 kg
Weight, process connection and antenna, MNPT/G ½, antenna 80 GHz; PTFE0.140 kg
Weight, process connection and antenna, MNPT/G ¾, antenna 80 GHz; PEEK0.195 kg
Weight, process connection and antenna, MNPT/G 1½, antenna 80 GHz; PEEK0.675 kg
Weight, process connection and antenna, G 1, antenna 80 GHz, PEEK0.260 kg
Weight, process connection and antenna, M24, antenna 80 GHz; PEEK0.155 kg
Weight, process connection and antenna, M24, antenna 180 GHz, PTFE0.180 kg
Weight, process connection and antenna, Tri-Clamp NA Connect ISO2852 DN25-38 (1½), antenna 80 GHz; PTFE0.320 kg
Weight, process connection and antenna, Tri-Clamp NA Connect ISO2852 DN40-51 (2), antenna 80 GHz; PTFE0.450 kg
Weight, process connection and antenna, NEUMO BioControl D50 PN16, antenna 80 GHz; PEEK0.890 kg
CertyfikatyEN 302372
Reflectormetal plate with diameter ≥ 1 m (40 in)
Sum of non-linearity, non-repeatability and hysteresis:±2 mm (±0.08 in)
Offset/zero point:±4 mm (±0.16 in)
Output, analogOnly relevant for 4-20mA current output; add error of the analog value to the di
Measured value resolutionDead band as per EN61298-2:
Digital:1 mm (0.04 in)
Tank height<20 m (66 ft)
Power consumptionTo meet device safety specifications according to the IEC/EN 61010 standard, the
Reference conditions• Ambient temperature TA = constant, in the range of +21 to +33 °C (+70 to +91 °
HART communication resistor250 Ω
Terminal voltage90 to 253 VAC (50 to 60 Hz)
Rmax500 Ω
Terminal voltage U at Maximum load R, depending on the supply voltage U0 at the supply unit10.4 to 35 V 3) 4) 5)
Terminal voltage U16 to 30 V
Maximum load R, depending on the supply voltage U0 of the power supply unit500 W
Permitted residual ripple with f = 100 to 10000 HzUSS < 10 mV
Resistance per channel2 × 0.5 Ω max.
Threshold DC voltage400 to 700 V
Threshold impulse voltage< 800 V
Capacitance at 1 MHz< 1.5 pF
Nominal arrest impulse voltage (8/20 μs)10 kA
Nominal current4 to 20 mA
OberflächenrauheitRa ≤3,2 µm (126 µin)
Fehlerverhalten (gemäß NAMUR-Empfehlung NE 43): Minimaler Alarm (= Werkseinstellung)3,6 mA
Fehlerverhalten (gemäß NAMUR-Empfehlung NE 43): Maximaler Alarm22 mA
Fehlerverhalten (gemäß NAMUR-Empfehlung NE 43): Fehlerverhalten mit frei einstellbarem Wert3,59 … 22,5 mA
Bürde4 … 20 mA HART
R L max1065 [W]
RLmax maximaler Bürdenwiderstand3 R L max £ U – 10.5 V
Masa4,4 kg (9,7 lb)
MateriałStahl, 316Ti (1.4571)
Öffnungen für alle Anschlüsse Vordereite G 2" (MNPT 2")62 mm (2,44 in)
Öffnung kann für einen beliebigen zusätzlichen Sensor verwendet werden22 mm (0,87 in)
Minimum bending radius100 mm (4)
Wymiary11 mm (in)
Cable entry10 (0.4) mm (in)
Ø42...601.65...2.36 mm
1224.8 mm
127...1405...5.51 mm
1616.34 mm
162...1756.38...6.89 mm
703.4 mm
862.8 mm