FMR245

Radar Level Gauge · Cargo Level & Temperature Gauging

Class-certified type (DNV register) · technical data sheet not yet verified​⁠​‌​⁠‍⁠‌​⁠⁠⁠​⁠​⁠​‌⁠
Specifications

Technical data.reference — unverified

Do you have the manufacturer datasheet for this model? Send it with the enquiry form — we check it and name the source.

Beam angle 10°
Temperature-40 °C to +200 °C
Pressure-1 bar to 16 bar
Weightapprox 7.4 kg + weight of flange
Material process connection316L (1.4435)
Material flange316L (1.4404 / 1.4435)
Material platingPTFE (conform to FDA 21 CFR 177.1550 and USP <88> Class VI)
Flange materialAISI 316L
Temperature stability properties13E0 in EN 1092-1 Tab. 18
Approval4-20mA SIL HART; 4-line display VU331, envelope curve display on site
Abstrahlwinkel α23°
Temperatur-40 °C ... +200 °C
Druck-1 ... 16 bar
Adapter304 (1.4301)
Process connection316L (1.4435)
Flansch316L (1.4404 / 1.4435)
PlattierungPTFE (FDA gelistetes TFM1600)
Abstrahlwinkel 23°
Operating frequencyabout 26 GHz
Beam angle α18°
Antenna size50 mm (2") mm (in)
D [mm (in)]44 (1.73)
H [mm (in)]< 500 (< 19.7)
Supply voltage9V
Max. voltage35 V
Device basic currentmax. 13 mA
Overvoltage protector600 V surge arrester
ResolutionDigital: 1 mm (0.04 in) / 0.03 % of measuring range
SealingFa. SHS: EPDM 70pW FKN
ScrewA2-70
Operating frequencyabout 26 GHz
Mounting position90°
Power supply16 ... 30 V DC
Antenna length1700MM mm
Signal4...20 mA
Device In-rush current≤15 mA
Arbeitsfrequenzca. 26 GHz
Versorgungsspannung16 ... 30 V DC
Antennentemperaturmax. 200°C
Ip-schutzartIP65
Weightca. 2,5 kg (5,51 lbs) + Flanschgewicht
Order CodeFMR2xx-14EALJAA2A
Ser.-no.12345678900
Ip65
Pn275 psi
T antenna max.200°C
Ln1700MM
Tamb > 70°C t >85°CXA099F-E
Dat./insp.34/04
Nennstrommax. 13 mA
Überspannungsschutz600 V Elektrodenableiter
StoßstromprüfungÎ = 10 kA, 10 Impulse
CertificationsIEC60079-27
Measuring range16...36 m
IP ratingIP65
Operating temperature-70°C
Storage temperature-85°C
Messgenauigkeit ReferenzbedingungenTemperatur = +20 °C ±5 °C (+68 °F ±41 °F)
AuflösungDigital: 1 mm (0.04 in) / 0,03 % des Messbereichs
Prozesstemperaturbereich-40 °C...+200 °C
Prozessdruckgrenze-1 bar...16 bar
Dielektrizitätszahl im Schwallrohrεr ≥ 1,4
Dielektrizitätszahl im Freifeldεr ≥ 1,9
Voltage16...36 V
Kegeldurchmesser (W)0,95 m
max. Messbereich40 m
Antennengröße50 mm
max. Spannung35 V
Einschaltstrom≤ 15 mA
Output signal4...20 mA
U4...20...36 mAV DC
Max.16...36 m
A>70°C
SeparatgehäuseFHX40 (IP 65)
Dimensions122x150x80 (HxBxT)
FISCO Pi5,5 W; mit Überspannungsschutz 1, 2 W
FISCO Li0,01 mH
Umgebungstemperatur-40 °C...+80 °C (-40 °F...+176 °F) bzw. -50 °C...+80 °C (58 °F...+176 °F)
Elektromagnetische Verträglichkeit (EMV)Elektromagnetische Verträglichkeit gemäß allen relevanten Anforderungen der EN61
Measuring distance (D)3 m (10 ft)
Weight for F23 housing + weight of flangeApprox. 7.4 kg
D [mm/inch]44 / 1.8
H [mm/inch]< 500 / < 20
Gap£ 0.04” in
Supply voltage - standard32 V
Supply voltage - EEx ia (FISCO model)17, 5 V
Supply voltage - EEx ia (Entity concept)24 V
Current consumption15 mA
Protection classIP 65
Max. cable length20 m (65 ft)
Temperature range-30 °C...+70 °C (-22 °F...158 °F)
MaterialsHousing: AlSi12; cable glands: nickle plated brass
Cable cross-section:0.5 to 2.5 mm (20 to 14 AWG)
Cable entry• Cable gland M20x1.5 (recommended cable diameter 6 ... 10 mm) • Cable entry G½
Basic current15 mA
In-rush current≤ 15 mA
FiscoUi 17,5 V Ii 500 mA; with
Maximum measured error– to 1 m: ± 10 mm
Valid as of software version01.05.00
Process connectionCFK DN50 PN10/16, PTFE>316L flange EN1092-1 (DIN2527) CMK DN80 PN10/16, PTFE
Output; OperationA 4-20mA SIL HART; 4-line display VU331, envelope curve display on site B 4-
HousingA F12 Alu, coated IP65 NEMA4X B F23 316L IP65 NEMA4X C T12 Alu, coated IP6
Beam angle18° / 10°
Max. measuring range20 m (65 ft) m (ft)
Min. measuring range5 m (16 ft) m (ft)
Antenna diameter50 mm (2")
Max. noise HART500 Hz...10 kHz: Ueff = 2.2 mV (at 500 Ω)
Reference operating temperature+20 °C (68 °F) ±5 °C (9 °F)
Reference operating relative humidity65 % ±20%
Resolution FMR 2451mm / 0.03 % of measuring range
Measuring range50 mm (2")
Reference operating conditions• temperature = +20 °C (68 °F) ±5 °C (9 °F)
Dielectric constant in a stilling wellεr ≥ 1,4
Dielectric constant in free spaceεr ≥ 1,9
Weight F23 housingapprox 7.4 kg + weight of flange
Measuring range4...20...36 mA
Messgenauigkeitbis 10 m ±3 mm, ab 10 m ±0,03% des Messbereichs
SchutzartIP 65, NEMA 4X (offenes Gehäuse: IP20, NEMA 1)
Impulse current test8/20 μs, Î = 10 kA, 10 pulses
Degree of protectionIP65, NEMA4X (higher degree of protection e.g. IP68 on request)
4...20 mA V DC16...36 U
T>85°C
mA DC4...20
T>85°C
max. zulässige Temperatur an der Antenne70 °C
Betriebsspannung16 ... 30 V DC
Ausgangssignal4...20 mA V DC
Ausgang; BedienungA 4-20mA SIL HART; 4-zeilige Anzeige VU331, Hüllkurvendarstellung vor Ort B
HousingA F12 Alu, besch. IP65 NEMA4X B F23 316L IP65 NEMA4X C T12 Alu, besch. IP6
Kabeleinführung2 Verschr. M20x1,5 (EEx d > Gewinde M20)
Fmr24550 mm (2")
Rotation speed< 60 U/min.
Messbereich [m (ft)]50 mm (2'')
Sendeleistung< 12 nW/cm2
D44 (1.73) mm (in)
H< 500 (< 19.7) mm (in)
Antennengröße (∅-Horn)50 mm (2")
Min. Bürde für HART-Kommunikation250
KabelverschraubungM20x1,5
Kommunikation - Stromaufnahme 4 mA16 V ... 36 V
Kommunikation - Stromaufnahme 20 mA7,5 V ... 36 V
Feststrom, frei einstellbar - Stromaufnahme11 mA ... 36 V
Kurzzeitige min. Anlaufspannung11.4 V
Anlaufstrom11 mA
Leistungsaufnahmemin. 60 mW, max. 900 mW
Ma4...20 mA
Max. Prozesstemperatur200 °C
max. empfohlener Messbereich20 m
BetriebsanleitungBA291F/00/de
Beschreibung der GerätefunktionenKA235F/00/a2
Mindestabstand zur Tankwand15 cm
Durchmesser50 mm (2'')
D [mm]44
H [mm]< 500
Ip-klasseIP65
TA >70°Ct >85°C
Klemmenspannung maximal32 V
Stromaufnahmemax. 13 mA
Betriebstemperatur>70°C
Speicherkapazität>85°C
FMR 2451mm / 0,03 % des Messbereichs
Max. measuring range =20 m (65 ft)
Min. measuring range =5 m (16 ft)
Minimum load for Hart communication250
Cable glandM20x1.5
Supply voltage minimal16 V
Supply voltage maximal36 V
Power consumption normal operation min60 mW
Power consumption normal operation max900 mW
Current consumption HART3.6...22 mA
HART connectionE+H RMA 422 / RN 221 N
Output4...20 mA
Type of antennaFMR245
max. Messbereich =20 m
WetterschutzIP65
Kabellänge20 m
Temperaturbereich-30 °C...+70 °C
WerkstoffeGehäuse: AlSi12; Kabelverschraubung: Messing, vernickelt
Messabweichungnicht für max. Messbereich = 70 m – bis 1 m: ± 10 mm; bei max. Messbereich = 20
Weight for F12 or T12 housing4 kg (8.82 lbs)
Weight for F23 housing7,4 kg (16.32 lbs)
Flange316L (1.4404 / 1.4435)
PlatingPTFE (FDA listed TFM1600)
Max. Temperaturt >85°C
Max. Druck275 psi
Max. Antennentemperatur200°C
Max. Messstrecke1700MM
Max. Temperatur Antenne200°C
Max. Länge1700MM
°45
Abgesetzte Anzeige und BedienungFHX40 (IP 65)
TAntenne max.D00899-A
Messbereich mit Zusatzausstattung D (E)40 m
Messbereich mit Zusatzausstattung F (G)70 m
max. measuring range (with option F)70 m
Measuring distance D3 m (9.8 ft)
Beam diameter W0.95 m (3.1 ft)
Minimum distance from marker400 (15.7)
Ambient temperature range-40 °C to +80 °C (-40 °F to +176 °F) or -50 °C to +80 °C (58 °F to +176 °F)
DIN EN 60079-14 bzw. IEC 60060-1Stoßstromprüfung 8/20 μs, Î = 10 kA, 10 Impulse
Average energy density< 12 nW/cm2
Antenna50mm/2", -40...200°C/-40...392°F, gas-tight feed through
Process ConnectionCFK DN50 PN10/16, PTFE>316L flange EN1092-1 (DIN2527)
Antenna diameter50 mm (2")
4...2.36
max. R20
Zulassungs-nr.D00882-A
SicherheitshinweisL00-FMR2xxxx-18-00-00-de-001
4...20 mA4...20 mA
Ip65IP65
Gewicht F23-Gehäuseca. 7,4 kg + Flanschgewicht
Dielectric constant• in a stilling well/Wave Guide antenna: εr ≥ 1,4 • in free space: εr ≥ 1,9
Order Code:FMR2xx-14EALJAA2A
Ser.-no.:12345678900
Mounting50 mm (2")
Process tank with agitatorSingle stage agitator <60 RPM
Recommendationmin. 400 mm / 160"
Supply voltage - HART standard 4 mA16 V
Supply voltage - HART standard 20 mA7.5 V
Supply voltage - EEx ia 4 mA16 V
Supply voltage - EEx ia 20 mA7.5 V
Supply voltage - EEx em 4 mA16 V
Supply voltage - EEx d 20 mA11 V
Supply voltage - Fixed current, adjustable standard 4 mA16 V
Supply voltage - Fixed current, adjustable EEx ia 4 mA16 V
Supply voltage - Fixed current, adjustable EEx ia 20 mA11 V
Supply voltage - Fixed current for HART standard 4 mA16 V
Supply voltage - Fixed current for HART EEx ia 4 mA16 V
Power consumption - Normal operation min60 mW
Power consumption - Normal operation max900 mW
Current consumption - HART3.6...22 mA
Influence of ambiente temperaturedigital output (HART, PROFIBUS PA, FOUNDATION Fieldbus): – FMR 24x average TK: 2
Maximum radiated pulsed energy1mW (average power output 1 μW)
Maximum radiated pulsed energy1 mW
max. abgestrahlte Pulsenergie1 mW
maximale abgestrahlte Pulsenergie1 mW
Einschaltspannung9V
Lift-off voltage9V
Klemmenspannung minimal9V
min. measuring range (with option F)5 m
maximal abgestrahlte Pulsenergie1 mW
Fehlerstrom FDE (Fault Disconnection Electronic)0 mA
Manufacturer documentation

Images from manufacturer documentation.

Photos, drawings and page previews from this model’s datasheet or catalog.

The Micropilot M is a compact radar level transmitter for the continuous, contactless measurement of liquids, pastes, sludge and solids.Source: Endress+Hauser FMR245 datasheet, p. 4

Applications

  • Process monitoring

Features

  • Electrostatic discharge protection

Options

  • Various antenna options
  • Different process connections
  • Special versions available

Standards

  • ATEX
  • FM
  • CSA
  • IECEx
  • NEPSI
Endress+Hauser FMR245 – Drawing (c7494ea0d557_S1-83 S. 1)
Drawing · c7494ea0d557_S1-83 · S. 1
Endress+Hauser FMR245 – Drawing (c7494ea0d557_S1-83 S. 2)
Drawing · c7494ea0d557_S1-83 · S. 2
Endress+Hauser FMR245 – Drawing (c7494ea0d557_S1-83 S. 4)
Drawing · c7494ea0d557_S1-83 · S. 4
Endress+Hauser FMR245 – Page preview (c7494ea0d557_S1-83 S. 3)
Page preview · c7494ea0d557_S1-83 · S. 3
Endress+Hauser FMR245 – Page preview (c7494ea0d557_S1-83 S. 5)
Page preview · c7494ea0d557_S1-83 · S. 5
Endress+Hauser FMR245 – Page preview (c7494ea0d557_S1-83 S. 6)
Page preview · c7494ea0d557_S1-83 · S. 6
Endress+Hauser FMR245 – Page preview (c7494ea0d557_S1-83 S. 7)
Page preview · c7494ea0d557_S1-83 · S. 7
Source: Endress+Hauser FMR245 datasheet, p. 75
Need this part?

Request a quote for this model.

Free of charge — send us your request for Endress+Hauser equipment. Our team checks it and replies by e-mail.

For marine equipment hardly any maker or authorised dealer will name a price while the vessel is unknown. With the vessel details, availability and price can be settled faster; without them we may have to ask first, which costs a few days. If you are not allowed to name the vessel, a photo of the rating plate is enough — attach it below or send it as a reply to our confirmation e-mail.

Your contact details are not published. No account required.
Related models

Also in Radar Level Gauge.

Other models of the same equipment type, Endress+Hauser first.

By manufacturer Endress+HauserKrohneEmerson RosemountVEGATokyo KeikiBarksdaleDanfossPanasiaSiemensNORIS AutomationEmersonHanla IMSHoneywellIfm ElectronicJUMOAll manufacturersSpare parts by equipmentNew here? Create a free account Can't read the plate? Try the nameplate scanner All Endress+Hauser models More like FMR245
More than the data sheet shows

We answer by e-mail, never with an automatic reply.

Tell us what you need for this Endress+Hauser FMR245 — a part, a service call, a second opinion. Are you Endress+Hauser? Claim this brand page.

Service engineer? Write the day report for this FMR245 in OceanSphere Work — photos, hours and parts, as a PDF for the owner. Try it free for 14 days →

Frequently asked

Questions that come up with this equipment.

Is this model's data free?

Yes. Specifications, documents and service notes for this model are readable without an account. An account adds saved searches and requests, nothing is taken away.

Can you find a part for this exact model?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.

The specifications look wrong — what now?

Send us the nameplate or the correct value. We check it against the manufacturer datasheet or class-society record and update the page.