Specifications

Technical data.reference — unverified

Do you have the manufacturer datasheet for this model? Send it with the enquiry form — we check it and name the source.

Operating Temp. & Humidity-10 ~40ºC, Humidity 20~88% RH (without condensing)
Sampling MethodSample Draw, approx. 0.5L/min
Audible Alarm95dbB (A) at 30cm
DisplayDigital LCD with auto backlight
Pump circuit Allowable voltage4.95 V
Pump circuit Allowable current1.12 A
Pump circuit Allowable power1138 mW
Toxic gas sensor circuit Allowable voltage4.95 V
Toxic gas sensor circuit Allowable current0.834 A
Toxic gas sensor circuit Allowable power853 mW
Buzzer circuit Allowable voltage4.95 V
Buzzer circuit Allowable current0.431 A
Buzzer circuit Allowable power441 mW
Main circuit Allowable voltage4.95 V
Main circuit Allowable current0.715 A
Main circuit Allowable power732 mW
Backup circuit Voltage3.0 VDC
Backup circuit Current10 µA
CertificationsTC20088
Ambient temperature range for use-20°C to +50°C
Ambient temperature range during battery charging0°C to +40°C
Backup battery typeCR1220
Pump circuit allowable voltage4.95 V
Pump circuit allowable current1.12 A
Pump circuit allowable power1138 mW
Toxic gas sensor circuit allowable voltage4.95 V
Toxic gas sensor circuit allowable current0.834 A
Toxic gas sensor circuit allowable power853 mW
Buzzer circuit allowable voltage4.95 V
Buzzer circuit allowable current0.431 A
Buzzer circuit allowable power441 mW
Main circuit allowable voltage4.95 V
Main circuit allowable current0.715 A
Main circuit allowable power732 mW
Backup circuit voltage3.0 VDC
Backup circuit current10 µA
Pump circuit maximum voltage4.95 V
Pump circuit maximum current1.12 A
Pump circuit maximum power1138 mW
Toxic gas sensor circuit maximum voltage4.95 V
Toxic gas sensor circuit maximum current0.834 A
Toxic gas sensor circuit maximum power853 mW
Buzzer circuit maximum voltage4.95 V
Buzzer circuit maximum current0.431 A
Buzzer circuit maximum power441 mW
Main circuit maximum voltage4.95 V
Main circuit maximum current0.715 A
Lithium ion battery pack (BP-8000)About 500 cycles
Suction flowAbove 0.5L/min
Alarm soundAbove95dB(A)(30cm)
Alarm-delay timeLess than 60sec(when introducing 1.6 times thicker gas than alarm preset point)
Power supplyDedicated dry battery unit <three AA batteries>【BUD-8000(S)】
Continuous operation timeBUD-8000(S):Approx.18hours(25℃・Non alarm operation)
Operating temperature-10〜40℃(non-rapidly-vary. It may differ according to mounted sensor.)
StructureDust and Water-proof Structure(IP67)
Explosion-proof approval No.TC20086(TIIS,Japan)
WeightApprox.1.0kg(BUD-8000(S) when in use)/Approx.1.1kg(BUL-8000(S) when in use)
Manufacturer documentation

Images from manufacturer documentation.

Photos, drawings and page previews from this model’s datasheet or catalog.

A portable toxic gas monitor designed to detect various toxic gases in the air.

Applications

  • industrial safety
  • marine safety
  • waste management

Features

  • detects multiple toxic gases
  • portable design
  • user manual included

Options

  • data logger management program

Standards

  • IEC 60079-0
  • EN60079-0
  • IEC 60079-11
  • EN60079-11
  • IEC 60079-26
  • EN60079-26
Source: RKI Instruments SC-8000 datasheet, p. 8
RKI Instruments SC-8000 – Photo (f11f3cf0a11f_S3-48 S. 3)
Photo · f11f3cf0a11f_S3-48 · S. 3
RKI Instruments SC-8000 – Photo (f11f3cf0a11f_S3-48 S. 9)
Photo · f11f3cf0a11f_S3-48 · S. 9
RKI Instruments SC-8000 – Photo (f11f3cf0a11f_S3-48 S. 9)
Photo · f11f3cf0a11f_S3-48 · S. 9
RKI Instruments SC-8000 – Photo (f11f3cf0a11f_S3-48 S. 13)
Photo · f11f3cf0a11f_S3-48 · S. 13
RKI Instruments SC-8000 – Photo (f11f3cf0a11f_S3-48 S. 15)
Photo · f11f3cf0a11f_S3-48 · S. 15
RKI Instruments SC-8000 – Drawing (f11f3cf0a11f_S3-48 S. 4)
Drawing · f11f3cf0a11f_S3-48 · S. 4
RKI Instruments SC-8000 – Drawing (f11f3cf0a11f_S3-48 S. 5)
Drawing · f11f3cf0a11f_S3-48 · S. 5
RKI Instruments SC-8000 – Drawing (f11f3cf0a11f_S3-48 S. 9)
Drawing · f11f3cf0a11f_S3-48 · S. 9
Source: RKI Instruments SC-8000 datasheet, p. 3
Need this part?

Request a quote for this model.

Free of charge — send us your request for RKI Instruments equipment. Our team checks it and replies by e-mail.

Makers and authorised dealers rarely quote marine equipment without the vessel. With these details we can check availability and prices faster; without them we may have to ask first, which can cost a few days. If you cannot share the vessel, a photo of the equipment’s rating plate does the same job — attach it below or send it as a reply to our confirmation e-mail.

Your contact details are not published. No account required.
Related models

Also in Gas Detection (Portable).

Other models of the same equipment type, RKI Instruments first.

By manufacturer RKI InstrumentsHanla IMSIndustrial ScientificDrägerDräger Safety AG & Co. KGaARiken KeikiRosemount Inc.AFRISOBW TechnologiesDetector Electronics Corporation (Det-Tronics)General MonitorsGreen InstrumentsHoneywell / RAE SystemsHoneywell AnalyticsMSAAll manufacturersSpare parts by equipmentNew here? Create a free account Can't read the plate? Try the nameplate scanner All RKI Instruments models More like SC-8000
Would you like to know more?

A person reads every request and replies by e-mail.

Tell us what you need for this RKI Instruments SC-8000 — a part, a service call, a second opinion. Are you RKI Instruments? Claim this brand page.

Service engineer? Write the day report for this SC-8000 in OceanSphere Work — photos, hours and parts, as a PDF for the owner. Try it free for 14 days →

Frequently asked

Three things people ask first.

Is this model's data free?

Yes. Specifications, documents and service notes for this model are readable without an account. An account adds saved searches and requests, nothing is taken away.

Can you find a part for this exact model?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.

The specifications look wrong — what now?

Send us the nameplate or the correct value. We check it against the manufacturer datasheet or class-society record and update the page.