MacGregor Finland Oy

ISO-socket, double, for C19A, Type: DM92B

A MacGregor Finland double‑socket AC reciprocating compressor (DM92B) designed for shipboard HVAC systems, featuring a C19A drive arrangement and ISO‑compatible connections.

Marine-rated, per Hersteller-Datenblatt
Capacity
Compressed Air / Refrigerant
Medium

Components & Design

Component data being added…

Technical Data

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Valve plate fatigue fracture after 4,000-6,000 operating hours
Piston ring wear with reduced delivery rate after 8,000-12,000 hours
Intercooler leakage due to vibration fatigue
Gearbox oil contamination by blow-by

Service & Maintenance

Overhaul valves every 4,000-6,000 hours. Piston rings every 8,000-12,000 hours. General overhaul every 16,000-20,000 hours. Oil change every 500 hours.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

MacGregor Finland Oy: keep valve sets and piston rings on board. Lead time: 2-6 weeks. Oil filters and seal kits as standard board inventory.
Equipment Model #1878 · ✓ still in production