OceanSphereFree accountLog inDEENPL
OceanSphereENGINES
Library› Cargo› Cargo Level & Temperature Gauging› Radar Level Gauge› Endress+Hauser Micropilot S FMR530

Micropilot S FMR530

Radar Level Gauge · Cargo Level & Temperature Gauging

Class-certified type (DNV register) · technical data sheet not yet verified
View photo ↗

The Micropilot FMR530 is used for highly accurate non-contact level measurement in storage tanks and can be applied in custody transfer applications. It meets the relevant requirements according to OIML R85 and API 3.1B. The FMR530 free space radar offers cost-effective and simple installation via 4-wire cable with HART and 24 V DC intrinsically safe power supply.

Specifications

Technical data.reference — unverified

Do you have the manufacturer datasheet for this model? Send it with the enquiry form — we check it and name the source.

Horn length0.1 (0.3) m (ft)
Safety distance0.1 (0.3) m (ft)
Blocking distance0.5 (1.6) m (ft)
A50 (1.97) mm (in)
Beam angle23°
Reference height of tank (GRH)3 m (9.8 ft)
Ambient temperature range-40 °C to +80 °C (-40 °F to +176 °F)
Ambient temperature for calibration to regulatory standards-25 °C to +55 °C (-30 °F to +140 °F)
Storage temperature-40 °C to +80 °C (-40 °F to +176 °F)
Degree of protectionIP68, NEMA 6P (open housing and removed liquid crystal display: IP20, NEMA 1)
Antenna:IP68 (NEMA 6P)
Vibration resistanceDIN EN 60068-2-64 / IEC 68-2-64: 20 to 2000 Hz, 1 (m/s2)2/Hz
Climate classDIN EN 60068-2-38 (test Z/AD)
CertificationsOIML R85
Ausgang4-20 mA
Linearisierungsfunktionmax. 32 Punkte
Energieversorgung4-20 mA mit HART
Leistungsaufnahme• Max. 330 mW bei 16 V • Max. 500 mW bei 24 V • Max. 600 mW bei 30 V • Max. 700
StromaufnahmeMax. 21 mA (50 mA Einschaltstrom)
Typische Genauigkeit±0,5 mm (2-Sigma-Wert)
Digital0,1 mm
Analog0,03 % des Messbereichs
Einschwingzeit15 Sekunden
Hysterese0,3 mm (0,01 in)
Wiederholbarkeit0,3 mm (0,01 in)
Maximale Befüllgeschwindigkeit100 mm/min
Fehlerstrom22 mA
WarnungE681
MarkierungenA: DN 150, ANSI 6"; B: DN 200...250, ANSI 8"...10"
Antennengröße150 mm (6"); 200 mm (8"); 250 mm (10")
D [mm (in)]146 (5,75); 191 (7,52); 241 (9,49)
H [mm (in)]< 180 (7,09); < 260 (10,2); < 350 (13,8)
UmgebungstemperaturbereichStandard: -40 °C...+80 °C (-40 °F...+176 °F)
KlimaklasseDIN EN 60068-2-38 (Prüfung Z/AD)
Schutzart• Antenne: IP65/68, NEMA 4X/6P
SchwingungsfestigkeitDIN EN 60068-2-64 / IEC 68-2-64: 20…2000 Hz, 1 (m/s2)2/Hz
EichzulassungenAlle Aspekte der OIML R85 werden erfüllt.
ProzessProzesstemperaturbereich -40 °C…+200 °C (-40 °F...392 °F)
Dielektrizitätszahlim Freifeld: r  1,9
CAntennenverlängerung: L1 = 100 (3,94); 200 (7,87); 300 (11,81); 400 (15,75) ...
Deckel (Display)AlSi10Mg
SealFa. SHS: EPDM 70pW FKN, Trelleborg: EPDM E7502/E7515
SichtscheibendichtungSilikondichtungsmasse Gomastit 402
StopfenPBT-GF30
Adapter316L (1.4435)
Deckel (Anschlussraum)AlSi10Mg
DeckeldichtungFa. SHS: EPDM 70pW FKN, Trelleborg: EPDM E7502/E7515
DichtringFa. SHS: EPDM 70pW FKN, Trelleborg: EPDM E7502/E7515
Anhängeschild304 (1.4301)
Typenschild316L (1.4404)
KerbnagelA4 (1.4571)
SchraubeA2-70
BetriebsanleitungBA00206F/00/DE
MaterialAlSi10Mg
Beschreibung der GerätefunktionenBA00217F/00/DE
Kurzanleitung (zur schnellen Inbetriebnahme)KA01055/00/DE2
Kurzanleitung (im Gerät)KA00161F/00/A2
Tank Side Monitor NRF590BA00256F/00/DE
SicherheitshinweiseXA00081F + WHG: ZE00243F/00/DE
Antenne; DichtungP 80mm/3", Kalrez, nicht leitende Medien
Process connectionCMJ DN80 PN10/16 B1, 316L Flansch EN1092-1 (DIN2527 C)
Abstrahlwinkel23°
Referenzhöhe des Tanks (GRH)150 mm (6")
Mm-genauigkeit4...20 mA HART
max. Befüllgeschwindigkeit100 mm Füllstandänderung / min
FunktionKorr. Rohrdurchm. (032)
Ausgangssignal4...20 mA
Output signal4…20 mA with HART protocol
Rauschen HART500 Hz...10 kHz: Ueff = 2,2 mV (bei 500 Ω)
Elektrische AnschlüsseGehäuse T12 mit separatem Anschlussraum
Bürde HARTMin. Bürde für HART-Kommunikation: 250 Ω
Kabeleinführung• Kabelverschraubung: 2 x M20x1,5 • Kabeleinführung: 2 x G½ oder 2 x ½NPT
Versorgungsspannung"Versorgungsspannung", → ä 22.
Speisung• Als "Stand alone" Version Speisung z. B. über zwei Endress+Hauser RN221N empfo
Prozesstemperaturbereich-40 °C...+200 °C
Prozessdruckgrenze0...40 bar (Option 64 bar)
Dielektrizitätszahl im Schwallrohrεr ≥ 1,4
Dielektrizitätszahl im Freifeldεr ≥ 1,9
Power supply24 VDC
Empty calibr.5.000 m
Full calibr.5.000 m
Span50 mm
Abstrahlwinkel α23°
empfohlener Tankwandabstand (W/2)0,6 m
Sicherheitsdistanz0,1 m
zusätzliche empfohlene Messbedingungen A50 mm
zusätzliche empfohlene Messbedingungen B0,5 m
zusätzliche empfohlene Messbedingungen C150...300 mm
Sicherheitsdistanz (SD)0,1 m
Min. Bürde für HART-Kommunikation250
Klemmenspannung (Standard)16 V - 36 V
Klemmenspannung (Ex)16 V - 30 V
Leistungsaufnahme (max)700 mW
Stromaufnahme (max)21 mA
Kommunikationsprotokoll4...20 mA HART
Abstand Flansch zu min. Füllstand5.000 m
Messspanne4.000 m
Galvanic isolation500 V towards ground. 500 V between power supply and signal
Electrical connectionHousing T 12 with separate terminal compartment
Supply voltagesee Page 30 ff.
Current consumptionMax. 21 mA (50 mA inrush current)
Dielectric constant• in a stilling well: εr ≥ 1.4 • in free space: εr ≥ 1.9
Wetted parts• Standard / Viton -20...+200 °C, for non-conductive media Antenna cone: PTFE We
Grundgewicht7,1 kg
Mehrgewicht0,5 kg
Absolute Genauigkeitbesser als ±1 mm (0,04 in)
Reaktionszeitmin. 1 s
Arbeitsfrequenzca. 6 GHz
maximale abgestrahlte Pulsenergie1 mW
maximal abgestrahlte Pulsenergie1 mW
Part numberFMR530
Manufacturer documentation

Images from manufacturer documentation.

Photos, drawings and page previews from this model’s datasheet or catalog.

The Micropilot S FMR530 is a radar-based level measurement system that uses time-of-flight technology to measure the distance from the reference point to the product surface.

Applications

  • liquid level measurement

Features

  • downward-looking measuring system
  • time-of-flight method
  • PulseMaster® software for signal identification
  • interference echo suppression

Options

  • stilling well
  • electronic suppression of interference echoes
  • antenna alignment
Source: Endress+Hauser Micropilot S FMR530 datasheet, p. 15

Standards

  • OIML R85
  • EN 61326
  • NAMUR recommendation EMC (NE21)
Source: Endress+Hauser Micropilot S FMR530 datasheet, p. 79
Endress+Hauser Micropilot S FMR530 – Photo (6e8a275adb61_S1-33 S. 1)
Photo · 6e8a275adb61_S1-33 · S. 1
Endress+Hauser Micropilot S FMR530 – Drawing (693fa21e504b_S5-25 S. 5)
Drawing · 693fa21e504b_S5-25 · S. 5
Endress+Hauser Micropilot S FMR530 – Drawing (693fa21e504b_S5-25 S. 6)
Drawing · 693fa21e504b_S5-25 · S. 6
Endress+Hauser Micropilot S FMR530 – Drawing (693fa21e504b_S5-25 S. 7)
Drawing · 693fa21e504b_S5-25 · S. 7
Endress+Hauser Micropilot S FMR530 – Page preview (693fa21e504b_S5-25 S. 8)
Page preview · 693fa21e504b_S5-25 · S. 8
Endress+Hauser Micropilot S FMR530 – Page preview (693fa21e504b_S5-25 S. 9)
Page preview · 693fa21e504b_S5-25 · S. 9
Endress+Hauser Micropilot S FMR530 – Page preview (693fa21e504b_S5-25 S. 10)
Page preview · 693fa21e504b_S5-25 · S. 10
Endress+Hauser Micropilot S FMR530 – Page preview (693fa21e504b_S5-25 S. 11)
Page preview · 693fa21e504b_S5-25 · S. 11
Source: Endress+Hauser Micropilot S FMR530 datasheet, p. 5
Need this part?

Request a quote for this model.

Free of charge — send us your request for Endress+Hauser equipment. Our team checks it and replies by e-mail.

Makers and authorised dealers rarely quote marine equipment without the vessel. With these details we can check availability and prices faster; without them we may have to ask first, which can cost a few days. If you cannot share the vessel, a photo of the equipment’s rating plate does the same job — attach it below or send it as a reply to our confirmation e-mail.

Your contact details are not published. No account required.
Related models

Also in Radar Level Gauge.

Other models of the same equipment type, Endress+Hauser first.

By manufacturer Endress+HauserKrohneEmerson RosemountVEGATokyo KeikiBarksdaleDanfossPanasiaSiemensNORIS AutomationEmersonHanla IMSHoneywellIfm ElectronicJUMOAll manufacturersSpare parts by equipmentNew here? Create a free account Can't read the plate? Try the nameplate scanner All Endress+Hauser models More like Micropilot S FMR530
Would you like to know more?

A person reads every request and replies by e-mail.

Tell us what you need for this Endress+Hauser Micropilot S FMR530 — a part, a service call, a second opinion. Are you Endress+Hauser? Claim this brand page.

Service engineer? Write the day report for this Micropilot S FMR530 in OceanSphere Work — photos, hours and parts, as a PDF for the owner. Try it free for 14 days →

Frequently asked

Three things people ask first.

Is this model's data free?

Yes. Specifications, documents and service notes for this model are readable without an account. An account adds saved searches and requests, nothing is taken away.

Can you find a part for this exact model?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.

The specifications look wrong — what now?

Send us the nameplate or the correct value. We check it against the manufacturer datasheet or class-society record and update the page.