OceanSphereFree accountLog inDEENPL
OceanSphereENGINES
Library› Cargo› Cargo Level & Temperature Gauging› Radar Level Gauge› Endress+Hauser FlexView FMA90

FlexView FMA90

Radar Level Gauge · Cargo Level & Temperature Gauging

Class-certified type (DNV register) · technical data sheet not yet verified
View photo ↗

FlexView FMA90 is a control unit for radar, ultrasonic and hydrostatic or universal 4-20 mA or HART level sensors. It connects up to two sensors simultaneously and provides 8 digital switching outputs for enhanced control. Available in field, DIN rail and panel housing variants, it ensures flexible installation in the field or control cabinet. Its robust design and intuitive touch operation make it ideal for water and wastewater as well as mining, minerals and metals applications.

Specifications

Technical data.reference — unverified

Do you have the manufacturer datasheet for this model? Send it with the enquiry form — we check it and name the source.

Distance between sensor membrane (reference point) and surface of liquid123 m³
Supply voltage (LPS):14 to 27 V (load-dependent)
Input resistor current measurement:25 Ω typ.
Internal HART communication resistor:330 Ω typ.
LoadMax. 600 Ω
Basic accuracy< 0.02 mA
Long-term drift< 0.02 mA/year
Output signal4 to 20 mA with HART, 0 to 20 mA without HART
Response to errorsMIN: 3.5 mA, MAX: Adjustable 21.5 to 22.5 mA
Supply voltage (AC voltage)85 to 253 VAC 50/60 Hz
Power consumption (AC voltage)Max. 20 VA
Supply voltage (DC voltage)10.5 to 32 VDC
Power consumption (DC voltage)Max. 15 VA
CertificationsUL/EN/IEC 61010-1, Section 9.4
Weightca. 1,6 … 1,8 kg (3,53 … 3,97 lb) je nach Gerätevariante
Anzeige3.5" TFT Touch-Anzeige
AuflösungQVGA, 76.800 Bildpunkte (320 x 240 Pixel)
Hintergrundbeleuchtung50.000 h Halbwertszeit (= halbe Helligkeit)
Anzahl der Farben24bit Farbtiefe; 16,7 Mio. darstellbare Farben
Maximale Zeichengröße; Anzahl der StellenZiffernhöhe max. 50 Pixel bzw. 13 mm bei max. 7 Stellen
BlickwinkelMax. Blickwinkelbereich: von der Display-Mittelpunktachse 85° in alle Richtungen
Degree of protection (field housing)IP65/NEMA type 4X
Inner diameter (d)100.0 to 100 000.0 mm
Factory setting1 000.0 mm
Brightness10 to 100 %
H flume4.5 ft
Minimum electronics temperature-150.0 to 200.0 °C
Maximum electronics temperature-150.0 to 200.0 °C
Start time72000 s
Gültig ab Version01.26-00
Versorgungsspannung85 … 253 VAC (50/60 Hz)
Leistungsaufnahmemax. 20 VA 230 VAC
Bestellmerkmal040 (Gehäuse); Option B (Schalttafeleinbau)
D123 m³
Schalttafelgehäuse (Schalttafelausschnitt)92 mm (3,62 in) x 92 mm (3,62 in) mm (in)
Einschaltgrenze0,0 … 200 000,0 %
Zuschaltintervall1 … 65 535 s
Nachlaufintervall0 ... 999 999 h
Nachlaufzeit0 ... 255 s
Eingabe0,1 … 125 000,0 mm
Werkseinstellung100,0 mm
Part numberFMA90
Manufacturer documentation

Images from manufacturer documentation.

Photos, drawings and page previews from this model’s datasheet or catalog.

Device for evaluating measured values and configuring Endress+Hauser sensors.

Applications

  • level measurement
  • flow measurement
  • pump control
  • rake control

Features

  • configures radar and hydrostatic level sensors
  • supports universal level sensors
  • provides digital value scaling

Options

  • Totalizer + pulses
Source: Endress+Hauser FlexView FMA90 datasheet, p. 10

Standards

  • UL/EN/IEC 61010-1, Section 9.4
Source: Endress+Hauser FlexView FMA90 datasheet, p. 15
Endress+Hauser FlexView FMA90 – Photo (e105daab4479_S1-52 S. 1)
Photo · e105daab4479_S1-52 · S. 1
Endress+Hauser FlexView FMA90 – Drawing (39757c46887e_S3-19 S. 3)
Drawing · 39757c46887e_S3-19 · S. 3
Endress+Hauser FlexView FMA90 – Drawing (39757c46887e_S3-19 S. 6)
Drawing · 39757c46887e_S3-19 · S. 6
Endress+Hauser FlexView FMA90 – Drawing (39757c46887e_S3-19 S. 8)
Drawing · 39757c46887e_S3-19 · S. 8
Endress+Hauser FlexView FMA90 – Page preview (39757c46887e_S3-19 S. 4)
Page preview · 39757c46887e_S3-19 · S. 4
Endress+Hauser FlexView FMA90 – Page preview (39757c46887e_S3-19 S. 5)
Page preview · 39757c46887e_S3-19 · S. 5
Endress+Hauser FlexView FMA90 – Page preview (39757c46887e_S3-19 S. 7)
Page preview · 39757c46887e_S3-19 · S. 7
Endress+Hauser FlexView FMA90 – Page preview (39757c46887e_S3-19 S. 9)
Page preview · 39757c46887e_S3-19 · S. 9
Source: Endress+Hauser FlexView FMA90 datasheet, p. 3
Need this part?

Request a quote for this model.

Free of charge — send us your request for Endress+Hauser equipment. Our team checks it and replies by e-mail.

Makers and authorised dealers rarely quote marine equipment without the vessel. With these details we can check availability and prices faster; without them we may have to ask first, which can cost a few days. If you cannot share the vessel, a photo of the equipment’s rating plate does the same job — attach it below or send it as a reply to our confirmation e-mail.

Your contact details are not published. No account required.
Related models

Also in Radar Level Gauge.

Other models of the same equipment type, Endress+Hauser first.

By manufacturer Endress+HauserKrohneEmerson RosemountVEGATokyo KeikiBarksdaleDanfossPanasiaSiemensNORIS AutomationEmersonHanla IMSHoneywellIfm ElectronicJUMOAll manufacturersSpare parts by equipmentNew here? Create a free account Can't read the plate? Try the nameplate scanner All Endress+Hauser models More like FlexView FMA90
Would you like to know more?

A person reads every request and replies by e-mail.

Tell us what you need for this Endress+Hauser FlexView FMA90 — a part, a service call, a second opinion. Are you Endress+Hauser? Claim this brand page.

Service engineer? Write the day report for this FlexView FMA90 in OceanSphere Work — photos, hours and parts, as a PDF for the owner. Try it free for 14 days →

Frequently asked

Three things people ask first.

Is this model's data free?

Yes. Specifications, documents and service notes for this model are readable without an account. An account adds saved searches and requests, nothing is taken away.

Can you find a part for this exact model?

Yes. Tell us the manufacturer, the model and what you need — a person reads every request and replies by e-mail.

The specifications look wrong — what now?

Send us the nameplate or the correct value. We check it against the manufacturer datasheet or class-society record and update the page.