"> Dräger Dräger FPS 7000 Full-Face Mask
⚓ Working on this equipment?
Ask the AI troubleshooter, log your hours on board and turn them into invoice-ready service reports — for this exact model.
Start free — 14 days →
No credit card required
🔧 1 verified suppliers & service companies for Dräger in the Maritime Network Find suppliers →
Dräger

Dräger FPS 7000 Full-Face Mask

The Dräger FPS 7000 is a full‑face fire‑fighter mask designed for shipboard firefighting, featuring an integrated speaking diaphragm and SOLAS‑approved protection against smoke and heat.

1 person
Capacity
Fire Suppression / Detection
Medium

Inspector Detail

Common issues

  • Exhalation or inhalation valve leakage causing a failed fit-check
  • Visor scratching, crazing or UV degradation reducing visibility, especially after outdoor locker storage
  • Head harness strap elasticity loss over time, affecting seal and quick-don ability
  • Speech diaphragm degradation reducing communication clarity
  • Facepiece rubber/silicone hardening or perishing with age, especially under temperature extremes
  • SCBA connector/thread damage preventing correct coupling

Inspection checklist

  • Visual inspection of facepiece, visor and straps for cracks, UV damage or perishing
  • Positive and negative pressure fit-check per Drager procedure
  • Inspect exhalation valve for damage, correct seating and free movement
  • Check head harness elasticity and adjustment buckles
  • Inspect SCBA connector/thread for damage and correct mating
  • Verify speech diaphragm integrity
  • Confirm mask is stored correctly and readily accessible per the fire control plan
  • Function test as part of the monthly fire equipment inspection

Service intervals

Fit-check and visual inspection monthly as part of fire equipment inspection
Full functional test with SCBA set per SOLAS fire drill schedule and manufacturer recommendation
Facepiece cleaning and disinfection after each use, and periodically per manufacturer's procedure
Manufacturer service/overhaul per Drager's recommended interval - confirm exact figure against current Drager FPS 7000 service documentation
Replacement (shelf life) per Drager's stated service life for the elastomer, tracked against date of manufacture

Typical wear limits

Visor condition renew on any crazing, deep scratching or reduced clarity that impairs vision - judgement-based per Drager inspection criteria, no fixed numeric limit
Head harness elasticity renew when straps no longer hold adjustment or show visible cracking - condition-based
Facepiece rubber renew on any hardening, cracking or loss of flexibility - condition and age based, confirm against Drager shelf-life guidance

Ranges are typical for this design class. Always confirm against the manufacturer documentation for your serial number.

Critical spares

  • Exhalation valve assembly
  • Head harness set
  • Visor (where approved as a separate replaceable part)
  • Speech diaphragm
  • SCBA connector seals/gaskets

Safety

  • A mask that fails a fit-check must be withdrawn from service immediately - never rely on a leaking facepiece in a smoke/toxic atmosphere
  • The facepiece must be matched to a correctly functioning, in-date SCBA set - it is not respiratory protection on its own
  • Verify crew familiarity with the storage location per the fire control plan - a mask that cannot be found quickly is a safety failure regardless of condition

Class survey

Firefighter's outfits and SCBA masks are checked at annual and renewal survey against SOLAS Ch. II-2 - class verifies quantity, location, in-date servicing/testing records and general condition; missing or out-of-date fit-check records are a common finding.

Estimated lifetime: Not meaningfully expressed in running hours - service life is governed by Drager's stated shelf life for the facepiece material and its condition at inspection; confirm against Drager FPS 7000 documentation and the date-of-manufacture marking on the specific unit

Components & Design

Component data being added…

Technical Data

type full_face_mask
solas True

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Lens scratching/crazing
Speaking diaphragm failure
Harness strap degradation
Inhalation valve sticking

Service & Maintenance

Annual fit test. Replace lens if scratched. Compatible with PSS series SCBA.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →

Replacement Parts

Dräger: Extinguishing agent and detector replacement per manufacturer. Lead time: 2-4 weeks.
Equipment Model #1571 · ✓ still in production