Taiko Kikai Industries USH-01 — 15 ppm bilge water separation for marine vessels of 340 GT and below; IMO MEPC.107(49) compliant oily water separator with integrated pump-motor.

Components & Design

Component data being added…

Technical Data

flow m3h 0.15
ppm 15
max pressure MPa 0.2
power VA 500
power supply AC100V / DC24V 10A (custom)
weight kg empty 120
weight kg operating 154

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Check coalescence filter (coalescer) for contamination, clogging or damage; replacement according to manufacturer's interval

Check coalescence filter (coalescer) for contamination, clogging or damage; replacement according to manufacturer's interval

Inspection of automatic oil discharge valve (solenoid valve) and oil level detector for proper function

Inspection of automatic oil discharge valve (solenoid valve) and oil level detector for proper function

Calibration and functional test of 15-ppm bilge alarm monitor (Oil Content Monitor / OCM) according to MEPC.107(49)

Calibration and functional test of 15-ppm bilge alarm monitor (Oil Content Monitor / OCM) according to MEPC.107(49)

Inspection and cleaning of pre-filter/strainer (strainer) upstream of separator inlet for foreign matter and deposits

Inspection and cleaning of pre-filter/strainer (strainer) upstream of separator inlet for foreign matter and deposits

Check all seals, flange connections and pipelines for leakage (oil and water discharge)

Check all seals, flange connections and pipelines for leakage (oil and water discharge)

Inspection of pressure gauges and automatic air vent valve (Air Vent Valve) for correct function and indicator accuracy

Inspection of pressure gauges and automatic air vent valve (Air Vent Valve) for correct function and indicator accuracy

Ensure correct routing of oil residue (slop) to bilge/sludge tank and proper recording in Oil Record Book (ORB) according to MARPOL

Ensure correct routing of oil residue (slop) to bilge/sludge tank and proper recording in Oil Record Book (ORB) according to MARPOL Annex I

Annual or class-prescribed overall inspection including type approval stamp, certificate validity check (MED, USCG, JG, CCS, CR) and check

Annual or class-prescribed overall inspection including type approval stamp, certificate validity check (MED, USCG, JG, CCS, CR) and check of all safety valves

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #152536 · ✓ still in production