Marinfloc

CD 1.0

Marinfloc CD 1.0 — Bilge water / oily water separation on commercial vessels; 1.0 m³/h capacity variant of the CD Unit series.

Components & Design

Component data being added…

Technical Data

flow m3h 1.0 (4660 litres/day)

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Verify Oil Content Meter (OCM / 15 ppm bilge alarm) calibration and function test using the manufacturer-approved test solution (e.g. Marinfloc WBS function tes

Verify Oil Content Meter (OCM / 15 ppm bilge alarm) calibration and function test using the manufacturer-approved test solution (e.g. Marinfloc WBS function test solution) at intervals required by class.

Inspect and replace filter cartridges (coalescence and polishing filters) according to service bulletin intervals or when differential pressure exceeds the spec

Inspect and replace filter cartridges (coalescence and polishing filters) according to service bulletin intervals or when differential pressure exceeds the specified limit; check for wrong filter material as per SB 17.

Check dosing pump hoses, flocculant chemical levels, and chemical dosing system operation; verify approved chemicals are in use per the manufacturer's approved

Check dosing pump hoses, flocculant chemical levels, and chemical dosing system operation; verify approved chemicals are in use per the manufacturer's approved chemical list.

Inspect all tank internals (oil descaler, flocculation tank, flotation tank) for corrosion, scaling, and sludge build-up; flush and clean as required — especial

Inspect all tank internals (oil descaler, flocculation tank, flotation tank) for corrosion, scaling, and sludge build-up; flush and clean as required — especially critical in high-chloride or high-temperature bilge water conditions (SB 01, SB 12, SB 24).

Verify the three-way overboard/recirculation valve operation and confirm correct sampling point arrangement and recirculation facility per SB 23 and MARPOL requ

Verify the three-way overboard/recirculation valve operation and confirm correct sampling point arrangement and recirculation facility per SB 23 and MARPOL requirements.

Check the compressed air supply system (pressure, moisture, oil-free quality) used for dissolved air flotation; inspect air distributor non-return valves as per

Check the compressed air supply system (pressure, moisture, oil-free quality) used for dissolved air flotation; inspect air distributor non-return valves as per SB 14 and settings for backflush timing per SB 13.

Review the Oil Record Book entries, WhiteBox / discharge monitoring unit logs, and confirm the 15 ppm alarm activates the automatic stop-and-recirculate functio

Review the Oil Record Book entries, WhiteBox / discharge monitoring unit logs, and confirm the 15 ppm alarm activates the automatic stop-and-recirculate function before any overboard valve opens.

Inspect all pump seals, piping connections, and magnetic flow meter installation for leaks or air ingress that could affect flow measurement accuracy (SB 18); t

Inspect all pump seals, piping connections, and magnetic flow meter installation for leaks or air ingress that could affect flow measurement accuracy (SB 18); test automatic oil-sensing and oil-release valve to sludge tank.

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #152507 · ✓ still in production

Wer liefert dieses Teil? 18 Betriebe im Verzeichnis · 8 aus Herstellerlisten

Global Services (Europe) Ltd
NoneUnited Kingdom
✓ autorisiert
Marinfloc AB
Varekil, Sweden
✓ autorisiert
Total Marine Solutions Inc
Fort Lauderdale, United States
✓ autorisiert
Vigil Marine Services
NoneUnited Arab Emirates
✓ autorisiert
ALMACO
ALMACO Group Inc
NoneUnited States|Finland|France
American Plumbing & Electrical Supply
NoneUnited States
City Electric Supply (National Account)
NoneUnited States
El shaddai shipping
NoneTogo
Gecom Genovese Commerciale Srl
Genova, Italy
HTS Hamburger Technik Service GmbH
NoneGermany|China|Japan|Brazil|South Korea|France
Intermarine LLC
New Orleans, United States
Weitere aus Hersteller- und Marktplatzverzeichnissen:
Global Services (Europe) Ltd · United KingdomVigil Marine Services · United Arab EmiratesAmerican Plumbing & Electrical Supply · United StatesEl shaddai shipping · TogoHTS Hamburger Technik Service GmbH · GermanyMIT (Marine & Industrial Transmissions Ltd) · United KingdomMSF Filtration and fluid products · GermanyWilhelmsen Ships Service - Global Account · Norway
Alle Betriebe für Marinfloc ansehen →