"> Corsa Performance Marine 6.5" HP Clamp-On Hi-Flo Muffler- 12752
⚓ Working on this equipment?
Ask the AI troubleshooter, log your hours on board and turn them into invoice-ready service reports — for this exact model.
Start free — 14 days →
No credit card required
🔧 1 verified suppliers & service companies for Corsa Performance Marine in the Maritime Network Find suppliers →
Corsa Performance Marine

6.5" HP Clamp-On Hi-Flo Muffler- 12752

Corsa Performance Marine 6.5" HP Clamp-On Hi-Flo Muffler- 12752 — Marine transom-mount or inline high-horsepower exhaust (clamp-on); engines up to 1000 HP; longer body for enhanced attenuation.

Components & Design

Component data being added…

Technical Data

inlet diameter in 4.00
body diameter in 6.50
transom exposure in 14.75
sound reduction dB 5-8
HP max 1000
finish Highly polished mirror finish
sold as Pair
price USD 2198

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Visual check of stainless steel outer casing for corrosion, cracks, deformations or pitting (especially at welds and inlet areas)

Visual check of stainless steel outer casing for corrosion, cracks, deformations or pitting (especially at welds and inlet areas)

Test inlet and outlet flanges and clamp/hose connections for integrity and secure fit (exhaust leaks can create CO hazard inside the vessel

Inspection of inlet and outlet flanges as well as clamp/hose connections for tightness and secure fit (exhaust leaks can create CO hazard inside the vessel)

Inspection of the internal damping insert (baffle/ASR spiral core) for deposits, coking, corrosion or mechanical damage from thermal shocks

Inspection of the internal damping insert (baffle/ASR spiral core) for deposits, coking, corrosion or mechanical damage from thermal shocks

Check of the Salisbury non-return valve (flapper) for free movement, tightness and wear; for tunable variants: functional check of the anti-su

Check of the Salisbury non-return valve (flapper) for free movement, tightness and wear; for tunable variants: functional check of the anti-surge valve (PN#10900)

Measurement of back pressure in the exhaust system for comparison with manufacturer limit values as an indicator of internal blockage or deposit formation

Measurement of back pressure in the exhaust system for comparison with manufacturer limit values as an indicator of internal blockage or deposit formation

Visual inspection of the transom installation area for water or exhaust backflow traces and check of the mounting hardware (bolts, brackets) for tightness un

Visual inspection of the transom installation area for water or exhaust backflow traces and check of the mounting hardware (bolts, brackets) for tightness and corrosion

Inspection of the high-gloss finish for discoloration or staining as an indicator of unusually high exhaust temperatures or faulty cooling

Inspection of the high-gloss finish for discoloration or staining as an indicator of unusually high exhaust temperatures or faulty cooling

Schallpegelmessung im Betrieb (dB) zum Vergleich mit den Herstellerangaben (z.B. 8-10 dB Reduktion), um signifikante Abweichungen als Hinweis auf interne Daempf

Schallpegelmessung im Betrieb (dB) zum Vergleich mit den Herstellerangaben (z.B. 8-10 dB Reduktion), um signifikante Abweichungen als Hinweis auf interne Daempfer-Degradation zu erkennen

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet