Leonardo DRS MarloAIR (Modular Air Handling Unit) — Pre-engineered modular commercial and industrial air handling unit for buildings including hospitals, pharmaceutical facilities, universities, manufacturing plants, government buildings, and aerospace/automotive facilities. Also listed in the Leonardo DRS marine/naval HVAC product portfolio (Marlo Heat Transfer Solutions division). Configurable via AHUMetrics software. Frames: military-grade extruded aluminum; base: 10-gauge stainless steel; wall panels: galvanized steel with 2-inch polyurethane foam insulation..

Components & Design

Component data being added…

Technical Data

airflow m3h 4250–95200 m³/h (2,500–56,000 CFM range)

🤖 Ask about this model

One free question — answered like a marine engineer. No account needed.

Common failures & inspection points

Inspect and clean evaporator and condenser coils for biofouling, scale, and corrosion — critical in high-salt marine environments

Inspect and clean evaporator and condenser coils for biofouling, scale, and corrosion — critical in high-salt marine environments

Check and replace air filters (HEPA/pre-filters) per schedule; verify filter housing seals and differential pressure across filter banks

Check and replace air filters (HEPA/pre-filters) per schedule; verify filter housing seals and differential pressure across filter banks

Inspect fan blades, bearings, and drive belts/couplings for wear, vibration, and balance; lubricate bearing assemblies as required

Inspect fan blades, bearings, and drive belts/couplings for wear, vibration, and balance; lubricate bearing assemblies as required

Verify seawater strainer on condenser cooling water inlet is clean and free of blockage; inspect sea-water condenser for corrosion and tube integrity

Verify seawater strainer on condenser cooling water inlet is clean and free of blockage; inspect sea-water condenser for corrosion and tube integrity

Check refrigerant charge level and inspect for leaks at all connections, valves, and fittings (R-134a / R-407a systems)

Check refrigerant charge level and inspect for leaks at all connections, valves, and fittings (R-134a / R-407a systems)

Inspect and test shock mounts and vibration isolators for degradation — essential for navy shock-hardened installations

Inspect and test shock mounts and vibration isolators for degradation — essential for navy shock-hardened installations

Verify operation of controls, thermostats, and remote controllers (MIL-C-2212 compliance where applicable); test safety interlocks and alarms

Verify operation of controls, thermostats, and remote controllers (MIL-C-2212 compliance where applicable); test safety interlocks and alarms

Inspect drain pans and condensate drain lines for blockage, corrosion, and proper slope; check insulation integrity on cold surfaces to prevent condensation and

Inspect drain pans and condensate drain lines for blockage, corrosion, and proper slope; check insulation integrity on cold surfaces to prevent condensation and corrosion

Type-general inspection and maintenance points for this equipment category — not model-specific.

Suppliers & Spare Parts

Direct links to manufacturer, datasheet, spare-parts portal and dealers — request access below.

📄 Request sourcing links & documents
🛠 Manage this equipment in your fleet

Cases, daily reports, timesheets and AI troubleshooting in the OceanSphere Marine app — free for 14 days.

Start free trial →
🔎 Suppliers & service for this equipment

Find manufacturers, repair shops and spare-part dealers in the Maritime Network — our global company directory.

Maritime Network →
Equipment Model #152242 · ✓ still in production